CabinetModule CR2016
18
CR2016
Characteristics of the outputs
Outputs
(B
H
, PWM)
■
Solid state outputs; positive switching (high side)
X20:01, 02, 03, 05
diagnostic capability (wire break and short circuit)
OUT 01...04
short-circuit and overload protection
can be configured as ...
switching voltage
10...32 V DC
switching current
0,1...2 A
total current
max. 8 A
■
PWM outputs (high side), variable frequency
PWM frequency
20...250 Hz
pulse duty factor
0...1000 ‰
resolution
1 ‰
switching current
0,1...2A (referred to the PWM value 1000 ‰)
total current
max. 8 A
Outputs
(B
H
)
■
Solid state outputs; positive switching (high side)
X20:09, 11, 13, 14
diagnostic capability (wire break and short circuit)
OUT 05...08
short-circuit and overload protection
X21:01, 02, 03, 05, 09, 11, 13, 14
switching voltage
10...32 V DC
OUT 09...16
switching current
0,1...2 A
can be configured as ...
total current
max. 16 A
■
PWM outputs (high side), fixed frequency
PWM frequency
100 Hz
pulse duty factor
0...100 %
resolution
10 %
switching current
0,1...2 A (referred to the PWM value 100 %)
total current
max. 16 A
Max. load resistance
25 kOhm
for a reliable wire break detection:
Note
Free-wheeling diode for the connection of inductive loads is integrated
OUT_GND is not connected with supply_GND in the unit
Wiring see data sheet page 5
Test standards and regulations
Climatic test
damp heat to EN 60068-2-30, test Db
(
≤
95 % rel. air humidity, non-condensing)
protection test to EN 60529
Mechanical resistance
vibration to EN 60068-2-6, test Fc
shock to EN 60068-2-27, test Ea
Immunity to
to ISO 7637-2, pulses 2, 3a, 3b, 4, severity level 4, function state A
conducted interference
to ISO 7637-2, pulse 5, severity level 1, function state A
to ISO 7637-2, pulse 1, severity level 4, function state C
Immunity to interfering fields
according to UN/ECE-R10 at 100 V/m (E1 type approval)
and DIN EN 61326 (CE)
Interference emission
to directive 06/28/EC (e1 type approval)
and DIN EN 61326 (CE)
Tests for the approval for railway applications
to BN 411 002 (DIN EN 50155 point10.2 and DIN EN 50121)
Control systems
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen
01.10.2015
We reserve the right to make technical alterations without prior notice!
CR2016 / page 4
EN 50155 clause 12.2 mechanical/climatic tests
EN 50121-3-2
EMC noise emission and noise immunity
additional information on request