17
CR2016
Characteristics of the inputs
Inputs
(B
L
, I
L
)
■
Digital inputs for positive sensor signals
X10:02, 04, 06, 08
switch-on level
0.7 U
B
IN 01...04
switch-off level
0.3 U
B
can be configured as...
input resistance
3.25 k
Ω
input frequency
max. 50 Hz
■
Frequency inputs for positive sensor signals
switch-on level
0.3...0.5 U
B
switch-off level
0.2 U
B
input resistance
3.25 k
Ω
measuring range
max. 2 kHz
accuracy
± 16 µs
Inputs
(B
L
)
■
Digital inputs for positive sensor signals
X10:02, 04, 06, 08
switch-on level
0.7 U
B
IN 05...08
switch-off level
0.3 U
B
can be configured as...
input resistance
3.25 k
Ω
input frequency
max. 50 Hz
Inputs
(B
L/H
)
■
Digital inputs for positive/negative sensor signals
X11:02, 04, 06, 08
switch-on level
0.7 U
B
IN 09...12
switch-off level
0.3 U
B
can be configured as...
input resistance
3.06 k
Ω
input frequency
max. 50 Hz
Inputs
(A)
■
Voltage inputs
X11:12, 14, 16, 18
input voltage
0...10/32 V
A_IN 01...04
resolution
10 bits
can be configured as...
input resistance
70/45 k
Ω
input frequency
max. 50 Hz
accuracy
± 1% FS
■
Current inputs
input current
0/4...20 mA
resolution
10 bits
input resistance
400
Ω
input frequency
max. 50 Hz
accuracy
± 1% FS
■
Ratiometric inputs for potentiometric transducers (e.g. joystick)
function
U
IN
÷ U
B
x 1000 ‰
value range
0...1000 ‰
■
Digital inputs for positive sensor signals
switch-on level
0.7 U
B
switch-off level
0.3 U
B
input resistance
45 k
Ω
input frequency
max. 50 Hz
Control systems
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen
01.10.2015
We reserve the right to make technical alterations without prior notice!
CR2016 / page 3