101-001 (iTDC), 101-002 (EIO88), 101-145 (iTDCSR) -73- Users Manual
IDTeck – iTDC 2~4 DOOR ACCESS CONTROLLER
☞
Doesn’t enter the Set-up Mode after entering the Master ID “00000000”.
Cause The Master ID might be changed or components are defective.
Solution 1. Try changing the Master ID through the application S/W. (It’ll be changed to “00000000”.)
- Note that the Master ID for iTDC-SR is 10 times <0>, “0000000000”.
2. When it is not feasible, initialise the unit as followings.
- Press the two System Initialisation Switches simultaneously while power is on.
- Wait until the message ‘Initialise END Turn OFF Power…’ appears on the LCD and turn it
off and on again. Try entering the Set-up mode.
- Note that all the value will be set to default, including the IDs after initialising.
3. If the trouble remains after the procedure above, contact a designated service centre.
☞
No problem with accessing by cards, but cannot access with the PIN input.
Cause An error in Set-up or possible component defect.
Solution 1. Check whether a beep sound is generated when you press a key.
When it is, the problem may be an error in set-up. Precede followings.
- Enter the Master ID (“00000000” default) to enter the Set-up mode.
(Note that the Master ID for iTDC-SR is 10 times <0>, “0000000000”.)
- Press <F1> key.
- ‘READER 1 MODE’ will appear on the LCD, then use the key <6> to choose ‘READER1
KEY IN’, ‘READER2 KEY IN’, ‘READER3 KEY IN’, or ‘READER4 KEY IN’ and select
‘Enable’ as wanted.
2. When there is no beep sound or already enabled Key-in functions, contact a designated service
centre.