8.1 INITIALIZATION OF iTDC
After the all installation and connections are completed, power up the iTDC then press the two
Initialisation Switches simultaneously. The LCD will first display “
System
Initialising…
” After the all
Initialisation process is completed then the LCD will display “
Initialise END Turn OFF Power.
” Turn the
power off then turn on again for iTDC running.
8.2 HOW TO ENTER THE SETUP MENU
To set-up or to change the iTDC settings, you have to enter the
SETUP MENU
first. To do so, press the
8
times <0>
key for
Master ID
(
Default setting “00000000”
) and
<ENT>
key from the optional Keypad
then you can get into
SETUP MENU
. There are 4 main
SETUP MENU
and you first get into
[SETUP
MENU F1]
. You can move to other
SETUP MENU
by pressing
<F1>
key for
[SETUP MENU F1]
,
<F2>
key for
[SETUP MENU F2]
,
<F3>
key for
[SETUP MENU F3]
and
<F4>
key for
[SETUP
MENU F4]
. There are several
SUB MENU
in the main
SETUP MENU
and you can scroll up and down
the
SUB MENU
by pressing
<4>
and
<6>
key in the main
SETUP MENU
. If you don’t press any key for
20 seconds or if you press
<ESC>
key then iTDC will exit the
SETUP MENU
then return to normal
operation. You can also change the
Master ID
in the
[SETUP MENU F2]
.
The
Master ID
for
iTDC-SR
is
10 times <0>
key (
Default setting “0000000000”
).
Initialize END
System