101-001 (iTDC), 101-002 (EIO88), 101-145 (iTDCSR) -34- Users Manual
IDTeck – iTDC 2~4 DOOR ACCESS CONTROLLER
4 Door Setting
Confirm the Reader and Exit Button locations as shown on the table below.
Note! This must be set-up first before other set-up.
8.4 DATE AND TIME SETTING
Select
[TIME SETTING]
in the
[SETUP MENU F2]
and enter the Year / Month / Date / hour / minute /
second / Day (Total 15 digits) as shown below. LCD will display the new Date and Time after the time
setting completed but year and day will not be displayed. iTDC has 24 hours system and day codes are 1
for Sunday, 2 for Monday, 3 for Tuesday, 4 for Wednesday, 5 for Thursday, 6 for Friday and 7 for
Saturday. The
Master ID
for
iTDC-SR
is
10 digits
number (
Default setting “0000000000”
).
8.5 ID COUNT SETTING
iTDC can register maximum 20,000 User ID and you can select maximum User ID to be registered into the
iTDC from 1,000 up to 20,000 Users in 1,000 increments. This ID COUNT setting is to configure
maximum User ID to be registered into iTDC and if you set-up less ID COUNT then iTDC will increase
the EVENT Buffer size to maximum. The default ID COUNT is 5,000 Users and the default EVENT
Buffer size is 27,500 can be stored when you operate iTDC off-line.
Entry
Exit
Door1
Reader #1
EXIT Button
Door2
Reader #2
EXIT Button
Door3
Reader #3
EXIT Button
Door4
Reader #4
EXIT Button
LCD displays after time setting
“
Year/Month/Day/Hour/Min./Sec./Day”
TIME SETTING
YYYYMMDDhhm
<ENT>
TIME SETTING
<ESC>
STAR iTDC
<ENT>
Initial Display
STAR iTDC [F1]
Press <F2>
Select [
TIME SETTING]
+ <ENT>
8 times <0> + <ENT>
“MASTER ID” + <ENT>