101-001 (iTDC), 101-002 (EIO88), 101-145 (iTDCSR) -33- Users Manual
IDTeck – iTDC 2~4 DOOR ACCESS CONTROLLER
8.3 DOOR SETTING
First, you have to configure “How many doors you want to control by iTDC” and this set-up is very
important, as the iTDC will automatically configure the Input sources and Output Relays upon to the
number of doors to be controlled by iTDC. Press
<F2>
key once then press
<6>
key or
<4>
key until the
LCD shows
[DOOR SETTING]
in the
[SETUP MENU F2]
then press
<ENT>
key to change the DOOR
SETTING. Please follow the steps below for DOOR SETTING and it shows the procedure for 4 DOOR
setting. The
Master ID
for
iTDC-SR
is
10 digits
number (
Default setting “0000000000”
).
2 Door Setting
Confirm the Reader locations as shown on the table below.
3 Door Setting
Confirm the Reader and Exit Button locations as shown on the table below.
Entry
Exit
Door1
Reader #1
Reader #2
Door2
Reader #3
Reader #4
Entry
Exit
Door1
Reader #1
Reader #2
Door2
Reader #3
EXIT Button
Door3
Reader #4
EXIT Button
Initial LCD Display
STAR iTDC [F1]
Press <F2> + 7times <6>
Select [
DOOR SETTING]
+ <ENT>
8 times <0> + <ENT>
“MASTER ID” + <ENT>
DOOR SETTING
DOOR SETTING
<ENT>
4 DOOR Setting Completed
DOOR SETTING
<ENT>
DOOR
<4> or
<6>
:
After Master ID change
:
Initial Master ID