27.08.2018
65 / 136
EVO S -
Installation and Servicing
Line No. Value
• Domestic hot water
menu
Adjust the comfort setting
Nominal setpoint
(1610) - - -
Adjust the DHW release mode
Release
(1620) 24h/day
• Activate the DHW mode
• Configuration
menu
Save the sensors
Save sensors
(6200)
Yes (switches back
to no automatically)
On RVS 63 :
• Menu
Configuration
Start heating circuit 1
Heating circuit 1
(5710)
On
Start heating circuit 2
Heating circuit 1
(5715)
On
Save the sensors
Save sensors
(6200)
Yes (switches back to
no automatically)
• LPB network
menu
Device number
Device address
(6600)
1
Segment number
Segment address
(6601)
1
Configure the bus supply
Bus power supply function
(6604)
Automatically
Set the clock program
Clock mode
(6640)
Slave without remote
setting
• Heating circuit 1 / 2
Adjust the comfort setting
Comfort setting temperature
(710/1010) - - -
Adjust the curve slope
Heating curve slope
(720/1020) - - -
•
Set the heating program to permanent comfort
Diagram: VF4
page 5 / 8