Hardware Configuration
Power On Sequence
The entry station takes approximately 60 seconds to boot after power has been supplied. Once booted, the screen
displays the customizable graphics page.
Defaulting the Entry Station
The entry station can be set back to its factory default settings using the following procedure:
1.
Reboot the entry station by removing and reapplying power.
2.
During the startup sequence, wait for the screen to go completely black, after the world logo disappears.
3.
Repeatedly tap the bottom quarter of the touchscreen until it displays
Default Settings
.
4.
Wait for the entry station to timeout. It will reset to the default configuration.
Defaulting the entry station does not reset the IP address. For instructions on how to reset the address, refer to
Temporarily Defaulting the IP Address
below.
Temporarily Defaulting the IP Address
The entry station IP address can be temporarily set to 192.168.111.222. If the currently configured IP address is
unknown, this allows you to connect to the web interface to view and/or change it.
The temporary IP address is used until the entry station is power cycled. After power cycling, the programmed IP
address is used.
Temporarily default the IP address using the following procedure:
1.
Reboot the entry station by removing and reapplying power.
2.
During the startup sequence, wait for the screen to go completely black, after the world logo disappears.
3.
Repeatedly tap the bottom quarter of the touchscreen until it displays
Temporary IP (192.168.111.222)
.
4.
Wait for the entry station to complete the boot sequence. When it starts it will use the following settings:
-
IP Address
: 192.168.111.222
-
Gateway
: 192.168.111.254
-
Net Mask
: 255.255.255.0
-
DHCP
: Disabled
5.
Connect to the web interface by entering 192.168.111.222 into the address bar of your web browser, and view or
change the IP address as required.
Temporarily defaulting the IP Address does not remove any programming. For instructions on how to reset the
entry station's programming, refer to
Defaulting the Entry Station
above.
PRT-ENTR-17 | Protege Vandal Resistant Touchscreen Entry Station | Installation Manual
22