A-18
A2
All Edevice confi guration commands and replies will result in RPC mes-
sages which are multiples of 4-byte lengths. Padding will occur following
the last data fi eld and may consist of any byte value.
When the Action boolean signals a read of a mode/value setting, the RPC
command must contain a dummy mode/value. While the mode/value in the
RPC command is not used, it must exist. If the mode/value is not contained
within the RPC command, an error status will result.
The successful modifi cation of a confi guration setting will result in the
change taking effect immediately, except where noted. Thus, it is strongly
advisable to not make confi guration changes if VXI-11 device links are
currently active. Doing so can cause unpredictable results and Edevice
misbehavior. However, such dynamic modifi cations may be desirable and
are possible at the discretion of the user. Messages that require rebooting
will not take affect until the Edevice is rebooted.
B.2
Edevice PROGRAM ID AND VERSION
The Edevice confi guration procedures shall use an RPC program ID of
1515151515 and an RPC version number of 1.