Ethernet I/O Modules
Step 2: Configuring I/O Pair-Connection on PETL/t(P)ET#2
1.
Select your
PETL/t(P)ET #2
and click “
Web
” button on the eSearch Utility to launch the browser
program for connecting to the web server.
2.
Enter the password (
default: Admin
) in the Login password field, and then click the
“Submit”
button to enter the configuration page.
3.
Click the
“Pair Connection
” link to enter the settings page.
4.
Select the “
Client
” option from the “
Server Mode
” drop down options.
5.
Type the
IP address of the PETL/t(P)ET #1
in “
Remote Server IP
” field.
6.
Type the
TCP Port of the PETL/t(P)ET #1
in “
Remote TCP Port
” field.
Refer to
Figures 5-2 to 5-4
for illustrations of how to perform the above steps.
7.
Type a
DI Count number for the PETL/t(P)ET #2
in the “
Local DI Count
” field.
For example, we set
“1”
in the
“Local DI Count”
field. This means the
DI x1 of PETL/t(P)ET #2
are
mapped to
DO x1 of PETL/t(P)ET #1,
refer to
Figure 5-6
for illustrations.
8.
Click the “
Submit
” button to complete the configuration.
Figure 5-6
7
8
ICP DAS CO., LTD.
PETL/tET/tPET DIO Series User Manual, Ver. 2.1, Sep. 2014, Page: 66