5.2 Two Modules Pushing the Local DI to each other
(1-to-1, Push mode)
Step 1: Configure the I/O Pair Connection on PETL/tET/tPET module #1
1.
In the eSearch Utility, select
PETL/tET/tPET module #1
, and then click the “
Web
” button to launch
the browser program and connect to the web server.
2.
Enter the password in the Login password field
(the default password is “Admin”)
, and then click
the
“Submit”
button to display the configuration page.
3.
Click the
“Pair Connection
” tab to display the Pair Connection settings page.
4.
In the I/O Pair Connection section, select “
Client
” from the “
Server Mode
” drop-down options.
5.
Enter the
IP address for PETL/tET/tPET module #2
in the “
Remote Server IP
” field.
6.
Enter the
TCP Port for PETL/tET/tPET module #2
in the “
Remote TCP Port
” field.
Refer to
Figures 5-2 to 5-4
for illustrations of how to perform the above procedure.
7.
Enter a
DI Count value for PETL/tET/tPET module #1
in the “
Local DI Count
” field of the “Local DI
to Remote DO” section.
For example, enter
“1”
in the
“Local DI Count”
field. This means
DI x1 of PETL/tET/tPET module #1
is mapped to
DO x1 of PETL/tET/tPET module #2
.
8.
Click the “
Submit
” button to complete the configuration.
ICP DAS CO., LTD.
PETL/tET/tPET DIO Series User Manual, Ver. 2.1, Sep. 2014, Page: 65