36
5
DOWNLOADING THE MEASUREMENT DATA
5.1
USB
•
The I-SAFE must be powered and in
“measure” or “demo” mode.
•
Press the settings encoder button for 3 seconds.
•
When the settings encoder display stops blinking, release the button.
•
The encoder display blinks quickly.
•
Then press the button to scroll through the menus (they scroll in a loop).
•
When the "d" menu appears on the encoder, wait 3 seconds, until the settings encoder display
shows "u".
•
Insert the USB stick into the USB port.
•
The I-SAFE writes the data file on the USB stick and the dot next to the "u" flashes.
•
Do not remove the USB stick while the dot flashes.
•
When the display shows "d" again, the USB stick can be unplugged.
•
Press the button again for 3 seconds and release when the display stops flashing.
•
Scroll through the menus again until the encoder displays the code of the desired display type
(-, =,
≡,
1, 2, 3 or 4) .
•
This code stays displayed and flashes every 5 seconds.
The unit begins to measure after 15 seconds and displays the speed of the approaching
vehicles, according to the chosen parameters.
5.2
B
LUETOOTH
PLEASE UNINSTALL ANY BLUESOLEIL DRIVER PREVIOUSLY INSTALLED ON YOUR
COMPUTER. IT IS NOT COMPATIBLE WITH THE ICOMSOFT I-SAFE.
As shown in Screenshot 17
, click on the “Download its data” button to start the data download from
the speed sign. Once the data downloaded, the software will ask whether to save the data locally, click
“Ok” and choose
the folder where to save the data. When the data is saved, the software will ask
whether you want to clear the speed sign’s memory. Click “Ok” to erase the memory.