Repeater lockout
This function helps prevent interference to other stations by
inhibiting your transmission when a signal is received. The
transceiver has two inhibiting conditions, repeater and busy.
q
Push [PWR] to turn power OFF.
w
While pushing [SET(LOCK)], turn power ON to enter initial
set mode.
e
Push [SET(LOCK)] several times until the “RLO” display
appears as shown below.
r
Rotate the tuning dial to turn the repeater lockout function
to “RP,” “BU” or OFF.
• “RP”: Transmit is inhibited when the tone squelch is closed.
• “BU”: Transmit is inhibited when a signal is received.
t
Push [PWR] to exit initial set mode.
■
Reversed duplex mode
When the reversed duplex mode is selected, the receive fre-
quency shifts.
(Transmit frequency shifts in normal duplex mode.)
Each receive and transmit frequency is shown in the table
below with the following conditions;
Input frequency
: 145.30 MHz
Direction
: – (negative)
Offset frequency : 0.6 MHz
q
Push [SET(LOCK] to enter set mode.
w
Push [SET(LOCK)] several times until the “REV” display
appears as shown below.
r
Rotate the tuning dial to turn the repeater lockout function
to ON or OFF.
t
Push [V/MHz(SCAN)] to exit set mode.
Reverse duplex mode is
turned ON.
USING
SET MODE
Auto repeater function is
turned OFF.
Auto repeater function is ON,
tone encoder is ON.
While pushing [SET(LOCK)],
turn power ON.
USING
INITIAL SET MODE
Reversed
OFF
ON
Rx frequency
145.30 MHz
144.70 MHz
Tx frequency
144.70 MHz
145.30 MHz
23
5
REPEATER OPERATION