131
12
OTHER FUNCTIONS
New2001
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
■
Cloning function
The IC-92A/92AD has transceiver-to-transceiver data clon-
ing capability. This function is useful when you want to copy
all of the programmed contents from one IC-92A/92AD to
another.
• An optional OPC-474
CLONING CABLE
is required.
q
Turn the transceiver’s power OFF, then connect an op-
tional OPC-474 between both
[SP]
jacks.
w
While pushing
[MR]
and
[MENU/
]
, push and hold
[PWR
] for 1 sec. to enter cloning mode.
• “CLONE M” appears.
e
Push
[PTT]
on the “master” transceiver.
•
“CLONE OUT M” appears and the bar meter shows that cloning
is taking place.
•
After the cloning is completed, the display returns to “CLONE
M.”
r
Push and hold
[PWR]
for 1 sec. to turn power OFF.
The optional RS-92
REMOTE CONTROL SOFTWARE
is also
available to clone/edit contents with a PC (for Microsoft
®
Windows
®
98/98SE/ME/2000XP) and using ICF format fi les.
Microsoft
®
and Windows
®
are registered trademarks of Microsoft Corporation
in the U.S.A. and other countries.
■
[DATA/MIC/SP] jacks
To connect external equipment such as speaker, micro-
phone, TNC, etc. refer to the diagram below.
The center terminal of
[MIC]
outputs 3.3 V DC via 330
resistor.
OPC-1751
OPC-1751
OPC-474
to the [SP] jack
to the [SP] jack
External
speaker
the
[SP]
jack
SP
SP
GND
3.5 (d) mm
plug
the
[MIC]
jack
33 k
330
MIC
MIC
GND
External
microphone
2.5 (d) mm
plug
PTT
3.3 V (See below)
Impedance 8
Impedance 2 k
MIC
3.0 V
MIC GND
INTERNAL SP
SP (AF OUT)
CLONE
SP GND
Summary of Contents for IC-92A