![Icom AP-3 Instruction Manual Download Page 76](http://html.mh-extra.com/html/icom/ap-3/ap-3_instruction-manual_612905076.webp)
UTILITY SOFTWARE
12
68
12-3 Using the Utility
In order to communicate with the Utility, the AP-3
must be started up in [Update Mode] according to the
following procedure:
1. Hold down the <MODE> button. Then supply power to
the AP-3 unit or lightly press and release the <RESET>
button.
• The [LAN] lamp and the
lamp will flash
in unison.
2. Release the <MODE> button when the <POWER>
indicator lamp starts flashing.
• The <POWER> lamp will continue to flash rapidly
while operating in [Setting Initialization Mode].
[NOTE]
When the AP-3 is started up
in [Update Mode], the WEP
function (i.e., wireless LAN
security level) will become
ineffective automatically.
ı
Connect the setting
terminal (computer)
After the AP-3 has been started up in [Update Mode],
connect the setting terminal (wired or wireless) con-
taining the Utility software to the AP-3 unit one-on-
one (i.e., all other network devices disconnected).
• The [LAN] lamp will illuminate if the setting terminal has
a wired connection with the AP-3.
• The
lamp will illuminate if the setting ter-
minal has a wireless connection with the AP-3.
* IP address conflicts and other network disruptions may
occur if the setting data is initialized or the firmware is
updated from a terminal connected to an operating net-
work.
Ç
Start up the utility
From Windows, click <Start> and select this Utility
from the [Program] menu. The [AP-3 Utility] screen is
displayed.
[AP-3 Utility] screen
q
w
e
r
t
y
u
Å
Start up the AP-3 in
[Update Mode]