46
[ 9 - 4 ] H e a t i n g ( L e f t )
[ 9 - 5 ] S e n s i n g ( L e f t )
[ 9 - 5 ] S e n s i n g ( L e f t )
[ 9 - 7 ] " L O W " ( L e f t )
a f t e r R e f r i . V a l v e
D i s c h a r g e T e m p
D i s c h a r g e T e m p
F u n c t i o n
3 . V a l v e C l o s e : 1 2 0 s e c
4 . V / V F u l l ON : Y E S
1 . W o r k i n g ? : O n
2 . C o n t r o l T e m p : 1 0 0 . 0 °C
3 . O p e r a t e T e m p : 1 0 . 0 °C
1 . D i s p l a y ? : O n
2 . I n i t i a l : 3 m i n
9-4-3: Refrigeration valve rest time setting
It sets the rest time of refrigeration valve that refrigerates
the raw material in the hopper.
Ice can be formed on the wall of the hopper when the
time of this category is too short, and the raw material in
the hopper may not be refrigerated when the time of this
category is too short.
9-4-4: Set up refrigeration valve ‘ Full OPEN’
Set up valve Full Open while refrigerating the raw
material in the hopper.
9-5/9-5-1: Refrigerants temperature use
Refrigerants temperature use can be set to ON/OFF.
This category needs to be activated first in order to
activate the category ‘ 4-31’.
When this category is activated and category ‘ 4-31’ is
not activated, the refrigerants temperature of ‘ 2-4’
may display error.
9-5-3: Refrigerants detection management temperature
When temperature reaches the reduced temperature
by the value set at these categories (9-5-2, 9-5-3) after
the compressor stopped at the value set at ‘ 9-5-2’ , the
compressor is operated again.
9-5-2: Refrigerants detection control temperature
When
‘ 9-5-1’ is activated, the temperature of the refrigerants set at this category is checked.
If the temperature is hotter, the operation of the compressor is stopped.
9-7/9-7-1:
‘LOW’ output use setting
Soft ice cream reaches the set value after the machine is
operated. When it does not reach the controlled value due
to other reasons (lack of raw material supply and so forth),
LOW message is displayed.
This category decides output.
9-7-2: Initial
‘LOW’ output time
When operating the machine for the first time, if soft ice cream is not made 100% with in the time
set at this category from the moment of 0.2A(9-7-6) increase from no load current (1-2), LOW is
displayed.(ex L90%)
Explanation of the function buttons(set by a user)
Summary of Contents for ISIV-273SHC
Page 4: ...4 Contents ...
Page 83: ...83 Method to Use Coin Mechanism ...
Page 84: ...84 Method to Use Coin Mechanism l g g ...
Page 110: ...110 Circuit diagram ...
Page 123: ...123 MEMO ...
Page 124: ...3240253 00 Online Internet Service http www icetro com SOFT ICE CREAM VENDING MACHINE ...