39
[ 4 - 2 6 ] H o p p e r ( L e f t )
[ 4 - 2 6 ] H o p p e r ( L e f t )
[ 4 - 2 7 ] S e n s i n g D r a w
[ 4 - 2 8 ] D e f r o s t ( L e f t )
[ 4 - 2 9 ] B o i l i n g ( L e f t )
[ 4 - 2 6 ] H o p p e r ( L e f t )
T e m p . C o r r e c t
T e m p . C o r r e c t
L e v e r
T e m p . C o r r e c t
1 . B e l o w 1 0 C : 0 . 0 C
2 . B e l o w 2 0 C : - 1 . 0 C
3 . B e l o w 3 0 C : - 2 . 0 C
4 . B e l o w 4 0 C : - 4 . 0 C
L e f t : 3 0 s e c
R i g h t : 3 0 s e c
1 . W o r k i n g ? : O n
2 . S e n s i n g T e m p : 1 0 . 0 C
3 . K e e p i n g T i m e : 3 m i n
1 . W o r k i n g ? : O n
2 . S e n s i n g T e m p : 6 0 . 0 C
3 . C o n t r o l T e m p : 2 . 0 C
5 . O v e r 4 0 C : - 5 . 0 C
4-26-3: Temperature compensation value setting for 30
℃
or lower
This sets the temperature compensation value of the
hopper to the environmental temperature of 30
℃
or
lower.
4-26-4: Temperature compensation value setting for 4
℃
or lower
This sets the temperature compensation value of
the hopper to the environmental temperature of 40
℃
or lower.
4-26-5: Temperature compensation value setting for 40
℃
or higher
This sets the temperature compensation value of
the hopper to the environmental temperature of 40
℃
or higher.
4-26-1: Temperature compensation value setting for 10
℃
or lower
This sets the temperature compensation value of the hopper
to the environmental temperature of 10
℃
or lower.
4-26-2: Temperature compensation value setting for 20
℃
or lower
This sets the temperature compensation value of the
hopper to the environmental temperature of 20
℃
or lower.
4-27: Sale lever no return judgment time setting
When the lever does not return to the original position after the
ejection of the soft ice cream, an alarm is set off after the time
that was set for this category.
4-28/4-28-1: Defrost function selection
The action function can be set to ON/OFF.
4-28-2: Cylinder temperature setting during defrost
Defrosting the soft freezer inside the cylinder to the
temperature that was set for this category.
4-28-3: Maintenance time setting during defrost
It sets the delay time after reaching the temperature of
‘4-28-2 ’ .
4-29/4-29-1: Water boiling function
Water boiling function can be set to ON/OFF.
Explanation of the function buttons (set by an Administrator)
4-26:
Hopper temperature compensation function setting
The temperature in the hopper is measured with the
temperature sensor on the floor of the hopper.
The temperature is correct in the models having an impeller, however it may have deviation
in the models without impeller.
As such, the temperature has to be corrected.
Summary of Contents for ISIV-273SHC
Page 4: ...4 Contents ...
Page 83: ...83 Method to Use Coin Mechanism ...
Page 84: ...84 Method to Use Coin Mechanism l g g ...
Page 110: ...110 Circuit diagram ...
Page 123: ...123 MEMO ...
Page 124: ...3240253 00 Online Internet Service http www icetro com SOFT ICE CREAM VENDING MACHINE ...