Parameter setting (setup) from front panel 

 

To open the parameters programming menu (setup): 

o

 

turn the unit in 

MAN 

mode and disconnect all the steps 

o

 

in normal measurements view, press 

 to call up the main menu  

o

 

select the icon 

. If it is disabled (displayed in grey) you must enter 

the password (see chapter 

Password access

). 

o

 

press 

 to open the setup menu. 

 

The table shown in the illustration is displayed, with the settings sub-

menus of all the parameters on the basis of their function. 

 

Select the required menu with keys ▲▼and confirm with 

 

Press ◄ to return to the values view. 

 

 

Settings: menu selection 

 
 

 

The following table lists the available submenus: 

 

Cod  MENU 

DESCRIPTION 

M01 

UTILITY 

Language, brightness, display pages etc. 

M02 

GENERAL 

Panel/plant data 

M03 

STEP 

Capacitor step configuration 

M04 

MASTER OUTPUTS 

Programmable outputs of master device 

M05 

MASTER / SLAVE 

Device role (master or slave) 

M06 

SLAVE 01 OUTPUTS   Programmable outputs of slave device 01 

… 

… 

 

M13 

SLAVE 08 OUTPUTS 

Programmable outputs of slave device 08 

M14 

PROG. INPUTS  

Programmable digital inputs 

M15 

PASSWORD 

Password access management 

M16 

COMMUNICATION 

Communication channels parameters 

M17 

BASE PROTECTIONS  Base protections of the panel  

M18 

HARMONIC PROT. 

Harmonic protections (EXP1016 module) 

M19 

MISCELLANEOUS 

Various settings 

M20 

LIMIT THRESHOLDS 

Limit thresholds on measurements 

M21 

COUNTERS 

Generic programmable counters 

M22 

ANALOG INPUTS  

Programmable analog inputs 

M23 

ANALOG OUTPUTS  

Programmable analog outputs 

M24 

ENERGY PULSES 

Pulses for energy meters increment 

M25 

USER ALARMS 

Programmable user alarms 

M26 

ALARM PROPERTIES  Action caused by alarms 

 

   

Настройка параметров на передней панели

 

 

Порядок открытия меню программирования параметров: 

o

 

переведите устройство в режим 

MAN (РУЧНОЙ) 

и отключите все ступени, 

o

 

в обычном представлении измерений нажмите 

, чтобы вызвать главное 

меню,  

o

 

выберите значок 

. Если значок не активен (серый), необходимо ввести 

пароль (см. главу 

Парольный доступ

), 

o

 

нажмите 

, чтобы открыть меню настройки. 

 

Показанная на рисунке таблица отображается с подменю всех параметров в 

зависимости от их функции. 

 

Выберите нужное меню с помощью кнопок ▲▼ и подтвердите выбор 

нажатием на 

 

Нажмите ◄, чтобы вернуться к просмотру значений. 

 

 

Настройки: выбор меню 

 

В следующей таблице перечислены подменю: 

 

Код

 

МЕНЮ

 

ОПИСАНИЕ

 

M01 

UTILITY 

Язык, яркость, страницы экрана и пр. 

M02 

GENERAL 

Данные устройства/установки 

M03

  STEP 

Настройка ступеней конденсаторов 

M04 

MASTER OUTPUTS 

Программируемые выходы ведущего 
устройства 

M05

  MASTER / SLAVE 

Роль устройства (ведущее или 
подчиненное) 

M06

  SLAVE 01 OUTPUTS  

Программируемые выходы подчиненного 
устройства 01 

 

… 

 

M13

  SLAVE 08 OUTPUTS 

Программируемые выходы подчиненного 
устройства 08 

M14

  PROG. INPUTS  

Программируемые цифровые входы 

M15

  PASSWORD 

Управление парольным доступом 

M16

  COMMUNICATION 

Параметры каналов связи 

M17

  BASE PROTECTIONS 

Базовая защита панели  

M18

  HARMONIC PROT. 

Защита от гармоник (модуль EXP1016) 

M19

  MISCELLANEOUS 

Прочие настройки 

M20

  LIMIT THRESHOLDS 

Пороговые пределы измерений 

M21

  COUNTERS 

Общие программируемые счетчики 

M22

  ANALOG INPUTS  

Программируемые аналоговые входы 

M23

  ANALOG OUTPUTS  

Программируемые аналоговые выходы 

M24

  ENERGY PULSES 

Импульсы увеличения показаний счетчиков 
энергии 

M25

  USER ALARMS 

Программируемые пользовательские 
аварийные сигналы 

M26

  ALARM PROPERTIES 

Действия, вызываемые аварийными 
сигналами 

 

 

Select the sub-menu and press  

 to show the parameters. 

 

Each parameter is shown with code, description and actual setting value. 

   

 

Выберите подменю и нажмите 

, чтобы показать параметры. 

 

Каждый параметр отображается с кодом, описанием и фактическим значением 

настройки. 

 

 

Set-up: parameter selection  

   

 

 

Настройка: выбор параметров

 

 

To modify the setting of one parameter, select it and then press 

.

  

 

If the Advanced level access code has not been entered, it will not be 
possible to enter editing page and an access denied message will be 
shown.  

 

If instead the access rights are confirmed, then the editing screen will be 
shown. 

   

 

Чтобы изменить настройку отдельного параметра, выберите его и нажмите 

.

  

 

Если код расширенного доступа введен не был, то пользователь не сможет 

войти на страницу изменения параметров, и ему будет показано сообщение о 
запрете доступа.  

 

После подтверждения прав доступа откроется экран изменения параметров.

 

 
 
 
 
 

     

 

     

Код параметра 

Описание 

параметра 

Текущее значение 

настройки 

Выбранный 

параметр 

Выбранный 

параметр 

Новое введенное 

значение 

Parameter code 

Parameter 

description 

Present setting 

value 

Selected parameter 

ЧП

 «

Профиэлектро

» 

Т

. +380 44 361-62-55, 80 

e-mail: [email protected] 

www. profielectro.net.ua 

Summary of Contents for RPC 8BGA

Page 1: ...Main menu 4 Password access 4 Display page navigation 5 Table of display pages 5 Harmonic analysis page 7 Waveform pages 7 Expandability 8 Additional resources 9 Communication channels 9 Inputs output...

Page 2: ...y outputs o Additional analog I O for PT100 temperature current voltage Capability to operate with several units interconnected in Master Slave mode o Maximum configuration Master 8 slave o Max 32 ste...

Page 3: ...t the step is not available because its reconnection time is not yet exhausted In this case sending a command to close the step number will flash to indicate that the operation has been confirmed and...

Page 4: ...d and the access is free If instead the passwords have been enabled and defined then to get access it is necessary to enter the password first specifying the numeric code through the keypad To enable...

Page 5: ...o the display remains were it was last You can set this function in menu M01 Utility M01 Utility Table of display pages PAGES EXAMPLE Home page Power Voltage and current Step life statistics Temperatu...

Page 6: ...function is disabled For example if the limit function is not programmed the corresponding page won t be shown Event time stamp Event description Event number total Key switches between Total Partial...

Page 7: ...eric format selecting the required order through and The lower part of the screen will display a little arrow that points to the selected column and the relative percentage value of the three phases T...

Page 8: ...figuration will be saved and will become effective otherwise the mismatch will be shown at every subsequent power on of the system The present system configuration is shown in the dedicated page of th...

Page 9: ...hernet RS485 DCRG RS 485 Ethernet DCRG Ethernet COM1 COM2 COM3 Gateway DCRG Gateway Inputs outputs internal variables counters analog inputs The inputs and outputs are identified by a code and a seque...

Page 10: ...is less than the Lower threshold for the programmed delay When the measured value becomes higher than the upper setpoint after the set delay the LIM status is reset Max function the upper threshold de...

Page 11: ...protections like panel or capacitor overtemperature no voltage release harmonic protections etc The maximum possible configuration is one master with 8 slaves Example 1 application in series It is req...

Page 12: ...gical step and pairing step between logical and physical outputs of the master and the slave The program is then automatically extended to the slaves On the slave it is only necessary to set the slave...

Page 13: ...8 guaranteeing the greatest safety for the operator o High speed data transfer o IP54 front panel o Limits the possibility of unauthorized access with device config Simply hold the CX dongle up to the...

Page 14: ...e panel M18 HARMONIC PROT Harmonic protections EXP1016 module M19 MISCELLANEOUS Various settings M20 LIMIT THRESHOLDS Limit thresholds on measurements M21 COUNTERS Generic programmable counters M22 AN...

Page 15: ...to go back to the parameter selection The entered value is stored Press to save all the settings and to quit the setup menu The controller executes a reset and returns to normal operation If the user...

Page 16: ...estore delay when no key pressed If set to OFF the display will always show the last page selected manually P01 08 Default page displayed on power up and after delay P01 09 Free text with alphanumeric...

Page 17: ...number of the step on the main page is shown in light gray P02 11 Connection sensitivity This parameter sets the speed of reaction of the controller With small values of P02 11 regulation is fast more...

Page 18: ...ws to avoid regulation oscillations Set this value according to the technical characteristics closing time declared by the manufacturer of the static contactor P02 30 Enables the setting of the setpoi...

Page 19: ...the previous parameter Example If the output function is set to Alarm Axx and you want this output to be energized for alarm A31 then P04 n 02 should be set to value 31 P04 n 3 Sets the state of the...

Page 20: ...4 PROGRAMMABLE INPUTS INPn n 1 8 UdM Default Range P14 n 01 INPn input function various see Input functions table P14 n 02 Function index x OFF OFF 1 99 P14 n 03 Contact type NO NO NC P14 n 04 Delay O...

Page 21: ...U Modbus ASCII Modbus TCP P16 n 06 IP address 192 168 1 1 000 000 000 000 255 255 255 255 P16 n 07 Subnet mask 255 255 255 0 000 000 000 000 255 255 255 255 P16 n 08 IP port 1001 0 9999 Note this menu...

Page 22: ...milar P17 08 Trip threshold for the capacitors overload protection alarm A08 that will arise after a integral delay time inversely proportional to the value of the overload P17 09 Threshold beyond whi...

Page 23: ...100 P18 n 08 5 1 100 P18 n 09 7 1 100 P18 n 10 11 1 100 P18 n 11 13 1 100 P18 n 12 1 55 0 212 P18 n 13 2 55 0 212 EXP1016 P18 n 01 P18 n 02 P18 n 03 2 1 P18 n 04 P18 n 05 P18 n 06 A11 P18 n 07 A12 P18...

Page 24: ...ould be connected to the appropriate terminal for the type selected See input module manual P22 n 02 and P22 n 03 Define the value to display for a min sensor signal in other words at the start of the...

Page 25: ...Active energy Kvarh Reactive energy kVA Apparent energy P24 n 02 The quantity of energy which must accumulate for a pulse to be emitted for example 10Wh 100Wh 1kWh etc P24 n 03 Pulse duration Applicat...

Page 26: ...function P26 n 10 Modem call A modem is connected as configured in setup P26 n 11 No LCD The alarm is managed normally but not shown on the display P26 n 12 13 Delay time Time delay in minutes or sec...

Page 27: ...eshold set with P18 n 11 A17 Harmonic protection Module nr n Temperature 1 too high The temperature 1 measured by the harmonic protection module is higher than threshold set with P18 n 12 A18 Harmonic...

Page 28: ...LOC 10 A19 LEN GEN 0 UAx GEN 0 Input function table The following table shows all the functions that can be attributed to the INPn programmable digital inputs Each input can be set for an reverse fun...

Page 29: ...Energised when global alarm 2 is active Global alarm 3 Energised when global alarm 3 is active Fan Panel ventilation fan Manual mode Active when the regulator is in MAN mode Automatic mode Active when...

Page 30: ...Senphi L3 26 W TOT Total active power 27 var TOT Total reactive power 28 VA TOT Total apparent power 29 Cosphi TOT Cosphi balanced three phase system 30 Senphi TOT Senphi balanced three phase system...

Page 31: ...he backup of user settings Once the required command has been selected press to execute it The device will prompt for a confirmation Pressing again the command will be executed To cancel the command e...

Page 32: ...arameter setting P02 03 Three phase P02 04 L3 P02 06 L1 L2 P02 22 LV P02 03 P02 04 L3 P02 06 L1 L2 P02 22 Single phase wiring SINGLE PHASE CONNECTION Voltage measure 1 phase voltage reading L1 N 1 L1...

Page 33: ...2 22 FULL THREE PHASE CONNECTION WITH NEUTRAL Wiring configuration used for standard applications with full three phase voltage control Voltage measure 3 ph to n and 3 ph to ph voltage readings L1 N L...

Page 34: ...V P02 23 ON P02 03 P02 04 L3 P02 06 L1 L2 P02 22 P02 23 Configuration with MV measurement and correction Voltage measure 3 ph to ph voltage reading L1 L2 L2 L3 L3 L1 on MV side 3 L1 L2 L2 L3 L3 L1 Cur...

Page 35: ...0 90 Capacitor overload current measure 3 Readings on L1 L2 L2 L3 L3 L1 3 L1 L2 L2 L3 L3 L1 Parameter setting P02 03 Three phase P02 04 L1 L2 L3 P02 06 L1 L2 L3 P02 22 LV P02 29 Fast P02 03 P02 04 L1...

Page 36: ...01 Stepx P07 1 01 Stepx P08 1 02 Stepx P05 01 COM1 P05 02 Slave01 P05 01 COM1 P05 02 Slave02 P05 01 COM1 P05 02 Slave03 P05 01 COM1 P05 02 P05 03 P05 04 P05 05 P04 1 01 x P06 1 01 x P07 1 01 x P08 1 0...

Page 37: ...morsetti OUT 1 600V 50 60 Hz OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 SLOT 1 SLOT 2 SLOT 3 SLOT 4 Dimensioni meccaniche e foratura pannello mm 380 44 361 62 55 80 e mail info profielectro net ua www...

Page 38: ...age 415V 415 Rated current AC1 5A 250V AC15 1 5A 415V AC1 5A 250 AC15 1 5A 415 Real time clock Energy storage Back up capacitors Operating time without supply voltage About 12 15 days 12 15 Insulation...

Page 39: ...phase neutral voltage 300V 300 Rev Date Notes 00 30 10 2012 First release 00 30 10 2012 01 28 01 2013 Added Tanfi parameters P02 30 e P02 31 01 28 01 2013 tanfi P02 30 P02 31 380 44 361 62 55 80 e ma...

Reviews: