M15 – PASSWORD
UoM
Default
Range
P15.01
Enable password
OFF
OFF-ON
P15.02
User level password
1000
0-9999
P15.03
Advanced level password
2000
0-9999
P15.04
Remote access password
OFF
OFF/1-9999
P15.01
– If set to OFF, password management is disabled and anyone has access to the
settings and commands menu.
P15.02
– With P15.01 enabled, this is the value to specify for activating user level access. See
Password access chapter.
P15.03
– As for P15.02, with reference to Advanced level access.
P15.04
– If set to a numeric value, this becomes the code to specify via serial communication
before sending commands from a remote control.
M15 – PASSWORD
Ед.
изм.
По ум.
Диапазон
P15.01
Установка пароля
ВЫКЛ.
ВЫКЛ.-ВКЛ.
P15.02
Пароль пользовательского
доступа
1000
0-9999
P15.03
Пароль расширенного
доступа
2000
0-9999
P15.04
Пароль удаленного доступа
ВЫКЛ.
ВЫКЛ./1-9999
P15.01
– Если задано ВЫКЛ., то управление паролями отключается, и меню настроек и
команд становится доступным любому пользователю.
P15.02
– При включенном параметре P15.01 здесь определяется значение для активации
пользовательского доступа. См. главу Парольный доступ.
P15.03
– В сравнении с параметром P15.02, этот параметр задает пароль расширенного
доступа.
P15.04
– Если выбрано числовое значение, то оно становится кодом, который
необходимо вводить по последовательному подключению, прежде чем можно
будет дистанционно выполнять команды.
M16 – COMMUNICATION
(COMn, n=1…2)
UoM
Default
Range
P16.n.01
Node serial address
01
01-255
P16.n.02
Serial speed
bps
9600
1200
2400
4800
9600
19200
38400
57600
115200
P16.n.03
Data format
8 bit – n
8 bit, no parity
8 bit, odd
8bit, even
7 bit, odd
7 bit, even
P16.n.04
Stop bits
1
1-2
P16.n.05
Protocol
(various)
Modbus RTU
Modbus ASCII
Modbus TCP
P16.n.06
IP address
192.168.1.1
000.000.000.000 –
255.255.255.255
P16.n.07
Subnet mask
255.255.255.0
000.000.000.000 –
255.255.255.255
P16.n.08
IP port
1001
0-9999
Note: this menu is divided into 2 sections for communication channels COM1..2.
The front IR communication port has fixed communication parameters, so no setup
menu is required.
P16.n.01
– Serial (node) address of the communication protocol.
P16.n.02
– Communication port transmission speed.
P16.n.03
– Data format. 7 bit settings can only be used for ASCII protocol.
P16.n.04
– Stop bit number.
P16.n.05
– Select communication protocol.
P16.n.06, P16.n.07, P16.n.08
– TCP-IP coordinates for applications with Ethernet interface.
Not used with other types of communication modules.
M16 – COMMUNICATION
(COMn, n=1…2)
Ед.
изм.
По ум.
Диапазон
P16.n.01
Последовательный
адрес узла
01
01-255
P16.n.02
Скорость
последовательной связи
бит/с
ек
9600
1200
2400
4800
9600
19200
38400
57600
115200
P16.n.03
Формат данных
8 бит – n
8 бит, без контроля
четности
8 бит, контроль по
нечетности
8 бит, контроль по
четности
7 бит, контроль по
нечетности
7 бит, контроль по
четности
P16.n.04
Стоповые биты
1
1-2
P16.n.05
Протокол
(разное)
Modbus RTU
Modbus ASCII
Modbus TCP
P16.n.06
IP-адрес
192.168.1.1
000.000.000.000 –
255.255.255.255
P16.n.07
Маска подсети
255.255.255.0
000.000.000.000 –
255.255.255.255
P16.n.08
IP-порт
1001
0-9999
Примечание. Это меню состоит из 2 частей для каналов связи COM1..2.
Передний IR-порт связи имеет фиксированные параметры подключения,
поэтому меню настройки для него не требуется.
P16.n.01
– Последовательный адрес (узла) протокола связи.
P16.n.02
– Скорость передачи данных портом связи.
P16.n.03
– Формат данных. Настройки 7 бит можно использовать только для протокола
ASCII.
P16.n.04
– Номер стопового бита.
P16.n.05
– Выбор протокола связи.
P16.n.06, P16.n.07, P16.n.08
– Настройки TCP-IP для устройств с интерфейсом Ethernet.
Не используются с другими типами модулей связи.
ЧП
«
Профиэлектро
»
Т
. +380 44 361-62-55, 80
e-mail: [email protected]
www. profielectro.net.ua