Table 23. Diagnostic error codes (continued)
Error code/symptom
Meaning
Part/action
035-XXX-S99
Failed RAID test on PCI slot
S
,
where
S
= number of failing
PCI slot. Check System Error
Log before replacing a part.
1. Adapter
2. SCSI backplane
3. Cable
035-XXX-SNN
Check System Error Log before
replacing a part.
s
= number of
failing PCI slot,
nn
= SCSI ID
of failing fixed disk.
Hard disk drive with SCSI ID
nn
on RAID adapter
in PCI slot
s
.
035-253-S99
RAID adapter initialization
failure.
1. ServeRAID adapter in slot
s
is not configured
correctly. Obtain the basic and extended
configuration status and see the
ServeRAID
User’s Reference
on the Documentation
CD-ROM for more information.
2. Cable.
3. SCSI backplane.
4. Adapter.
075-XXX-000
Failed power supply test.
Power supply
089-XXX-001
Failed microprocessor test.
1. VRM 1 for microprocessor 1
2. Microprocessor 1
089-XXX-002
Failed optional microprocessor
test.
1. VRM 2 for optional microprocessor 2
2. Optional microprocessor 2
166-198-000 System
Management: Aborted
Unable to communicate with
ASM. It might be busy. Run the
test again.
1. Run the diagnostic test again.
2. Correct other error conditions and retry. These
include other failed system management tests
and items logged in the System Error Log of
the optional Remote Supervisor Adapter.
3. Disconnect all engine and option power cords
from the engine, wait 30 seconds, reconnect,
and retry.
4. Remote Supervisor Adapter, if installed.
5. System board.
166-201-001 System
Management: Failed
I
2
C bus error(s). See
SERVPROC and DIAGS
entries in event log.
1. If installed, reseat the I
2
C cable between the
Remote Supervisor Adapter (in PCI slot 1/J32)
and the system board (J27).
2. Reseat memory DIMMs.
3. Memory DIMMs.
4. System board.
166-201-002 System
Management: Failed
I
2
C bus error(s) See
SERVPROC and DIAGS
entries in event log.
1. Reseat I
2
C cable between the operator
information panel and the system board (J24).
2. Reseat I
2
C cable between the diagnostics
panel and the system board (J23).
3. Operator information panel.
4. Diagnostics panel.
5. System board.
132
NAS Gateway 300 User’s Reference
Summary of Contents for TotalStorage NAS 300
Page 1: ...TotalStorage NAS Gateway 300 Model G27 User s Reference GA27 4321 00...
Page 8: ...viii NAS Gateway 300 User s Reference...
Page 10: ...x NAS Gateway 300 User s Reference...
Page 14: ...xiv NAS Gateway 300 User s Reference...
Page 26: ...12 NAS Gateway 300 User s Reference...
Page 40: ...26 NAS Gateway 300 User s Reference...
Page 46: ...32 NAS Gateway 300 User s Reference...
Page 68: ...54 NAS Gateway 300 User s Reference...
Page 134: ...120 NAS Gateway 300 User s Reference...
Page 136: ...122 NAS Gateway 300 User s Reference...
Page 168: ...154 NAS Gateway 300 User s Reference...
Page 182: ...168 NAS Gateway 300 User s Reference...
Page 199: ......