Table 22. Storage unit troubleshooting table (continued)
Problem Indicator
Component
Possible Cause
Possible Solutions
Intermittent or
sporadic power loss to
the expansion unit
Some or all CRUs Defective AC
power source or
partially plugged
in power cord
1. Check the AC power
source.
2. Reseat all installed
power cables and power
supplies.
3. If applicable, check the
power components
(power units, UPS, and
so on).
4. Replace defective power
cords.
Power supply
failure
Check for a Fault LED on
the power supply and
replace the failed CRU.
Midplane failure
Have the midplane replaced
(service technician only).
Unable to access
drives
Drives and FC
loop
Incorrect ID
settings
1. Ensure that the FC
optical cables are
undamaged and
properly connected.
2. Check the drive ID
settings.
Note:
Change switch
position only when the
expansion unit is powered
off.
ESM board failure Have one or both ESM
boards replaced.
Random errors
Subsystem
Midplane failure
Have the midplane replaced
(service technician only).
Note:
If you cannot find the problem in the troubleshooting table, test the entire
system. See your storage unit documentation for more detailed information
on testing and diagnostic tools.
Chapter 8. Troubleshooting
121
Summary of Contents for totalstorage 326
Page 8: ...viii Model 326 User s Reference...
Page 10: ...x Model 326 User s Reference...
Page 20: ...8 Model 326 User s Reference...
Page 64: ...52 Model 326 User s Reference...
Page 88: ...76 Model 326 User s Reference...
Page 134: ...122 Model 326 User s Reference...
Page 144: ...132 Model 326 User s Reference...
Page 146: ...134 Model 326 User s Reference...
Page 166: ...154 Model 326 User s Reference...
Page 182: ...170 Model 326 User s Reference...
Page 192: ...180 Model 326 User s Reference...
Page 214: ...202 Model 326 User s Reference...
Page 232: ...220 Model 326 User s Reference...
Page 238: ...226 Model 326 User s Reference...
Page 239: ......