Table 28. Diagnostic error messages (continued)
Error Code
Meaning
FRU/action
166-198-000
System Management
aborted: (Unable to
communicate with the
Remote Supervisor Adapter.
It may be busy. Run the test
again). (Communication with
the Remote Supervisor
Adapter has failed).
1.
Re-run the Diagnostic Test
2. Fix other error conditions and retry. These include other
Failed System Management tests and items logged in the
optional Remote Supervisor Adapter’s System Error Log
3. Disconnect all server and option power cords from the
unit, wait 30 seconds, reconnect, and retry.
4. Remote Supervisor Adapter, if installed
5. System board
166-201-001
System Management failed:
(I2C Bus Error(s))
(ISMP indicates I2C errors on
bus 0. Potential FRUs:
Memory DIMMs, system
board)
1.
If installed, reseat I2C cable between Remote
Supervisor Adapter (in PCI slot 1/J44) and system
board
2. Reseat memory DIMMs
3. Memory DIMMS
4. System board
166-201-002
System Management failed:
(I2C Bus Error(s))
(ISMP indicates I2C errors on
bus 2. Potential FRUs: LED
front panel, system board).
1.
Reseat I2C cable between operator information panel
and system board (J39)
2. Operator information panel
3. System board
166-201-003
System Management failed:
(I2C Bus Error(s))
(ISMP indicates I2C errors on
bus 3. Potential FRUs: power
backplane, system board).
1.
Reseat cables between power backplane and system
board
2. Operator information panel
3. System board
166-201-004
System Management failed:
(I2C Bus Error(s))
(ISMP indicates I2C errors on
bus 4. Potential FRUs: DASD
backplane, system board).
1.
If installed, reseat I2C cable between IBM Netfinity
3-Pack Ultra160 Hot-Swap Expansion Kit and DASD
backplane and DASD I2C on system board (J0)
2. System board
166-201-005
System Management failed:
(I2C Bus Error(s))
(ISMP indicates I2C errors on
bus 0, 1, or 5. Potential
FRUs: Memory DIMMs,
CPUs, system board).
1.
Reseat Memory DIMMs
2. Reseat processors
3. Memory DIMMs
4. Processors
5. System board
166-260-000
System Management failed:
(Unable to restart Remote
Supervisor Adapter). Restart
Remote Supervisor Adapter
Error. After restarting,
Remote Supervisor Adapter
communication was lost.
Unplug and cold boot to reset
the Remote Supervisor
Adapter).
1.
Disconnect all server and option power cords from
server, wait 30 seconds, reconnect, and retry.
2. Reseat the Remote Supervisor Adapter in PCI slot 1/J44.
3. Remote Supervisor Adapter
150
Model 326 User’s Reference
Summary of Contents for totalstorage 326
Page 8: ...viii Model 326 User s Reference...
Page 10: ...x Model 326 User s Reference...
Page 20: ...8 Model 326 User s Reference...
Page 64: ...52 Model 326 User s Reference...
Page 88: ...76 Model 326 User s Reference...
Page 134: ...122 Model 326 User s Reference...
Page 144: ...132 Model 326 User s Reference...
Page 146: ...134 Model 326 User s Reference...
Page 166: ...154 Model 326 User s Reference...
Page 182: ...170 Model 326 User s Reference...
Page 192: ...180 Model 326 User s Reference...
Page 214: ...202 Model 326 User s Reference...
Page 232: ...220 Model 326 User s Reference...
Page 238: ...226 Model 326 User s Reference...
Page 239: ......