Table 7. Power supply LEDs
AC Good
LED
DC Good
LED
Description
FRU/action
Off
Off
No power to system
or AC problem.
1.
Check AC power to system.
2. Power supply
On
Off
Standby mode or DC
problem.
1.
Check system board cable
connectors J32, J33, and J35.
Move jumper on J32’s extension
cable to pins 2-3 to bypass
power control. If the DC Good
LED comes on, press
Ctrl
+
Alt
+
Delete
. Watch the
screen for any POST errors.
Check the System Event/Error
Log for any listed problems. If
the system powers up with no
errors:
a.
Power switch assembly
b.
System board
2. Remove the adapters and
disconnect the cables and power
connectors to all internal and
external devices. Power-on the
system. If the DC Good LED
comes on, replace the adapters
and devices one at a time until
you isolate the problem.
3. Power supply
4. Power backplane
5. System board
On
On
Power is OK.
N/A
Chapter 8. Troubleshooting
87
Summary of Contents for totalstorage 326
Page 8: ...viii Model 326 User s Reference...
Page 10: ...x Model 326 User s Reference...
Page 20: ...8 Model 326 User s Reference...
Page 64: ...52 Model 326 User s Reference...
Page 88: ...76 Model 326 User s Reference...
Page 134: ...122 Model 326 User s Reference...
Page 144: ...132 Model 326 User s Reference...
Page 146: ...134 Model 326 User s Reference...
Page 166: ...154 Model 326 User s Reference...
Page 182: ...170 Model 326 User s Reference...
Page 192: ...180 Model 326 User s Reference...
Page 214: ...202 Model 326 User s Reference...
Page 232: ...220 Model 326 User s Reference...
Page 238: ...226 Model 326 User s Reference...
Page 239: ......