Table 47. Five-adapter configuration (continued)
Configuration
PCI Slot-1
(32-bit,
33-MHz)
PCI
Slot-2(64-
bit, 33-MHz)
PCI
Slot-3(64-
bit, 33-MHz)
PCI Slot-4
(64-bit,
66-MHz)
PCI Slot-5
(64-bit,
66-MHz)
Ethernet, Ethernet, Gigabit, ServeRAID,
FC2
Ethernet
Ethernet
ServeRAID
Gigabit
FC2
Ethernet, Ethernet, PRO/1000,
ServeRAID, FC2
Ethernet
Ethernet
ServeRAID
PRO/1000
FC2
Ethernet, Ethernet, Gigabit, ServeRAID,
FC1
Ethernet
Ethernet
ServeRAID
Gigabit
FC1
Ethernet, Ethernet, PRO/1000,
ServeRAID, FC1
Ethernet
Ethernet
ServeRAID
PRO/1000
FC1
Ethernet, Ethernet, Gigabit, FC2, FC1
Ethernet
Ethernet
Gigabit
FC1
FC2
Ethernet, Ethernet, PRO/1000, FC2, FC1
Ethernet
PRO/1000
Ethernet
FC1
FC2
Ethernet, Ethernet, Gigabit, FC1, FC1
Ethernet
Ethernet
Gigabit
FC1
FC1
Ethernet, Ethernet, PRO/1000, FC1, FC1
Ethernet
Ethernet
PRO/1000
FC1
FC1
Ethernet, Ethernet, SCSI LVD/SE,
ServeRAID, FC2
Ethernet
SCSI
LVD/SE
Ethernet
ServeRAID
FC2
Ethernet, Ethernet, SCSI HVD,
ServeRAID, FC2
Ethernet
SCSI HVD
Ethernet
ServeRAID
FC2
Ethernet, Ethernet, SCSI LVD/SE,
ServeRAID, FC1
Ethernet
SCSI
LVD/SE
Ethernet
ServeRAID
FC1
Ethernet, Ethernet, SCSI HVD,
ServeRAID, FC1
Ethernet
SCSI HVD
Ethernet
ServeRAID
FC1
Ethernet, Ethernet, SCSI LVD/SE, FC1,
FC1
Ethernet
SCSI
LVD/SE
Ethernet
FC1
FC1
Ethernet, Ethernet, SCSI HVD, FC1, FC1
Ethernet
SCSI HVD
Ethernet
FC1
FC1
Ethernet, Ethernet, ServeRAID, FC2, FC1 Ethernet
ServeRAID
Ethernet
FC1
FC2
Ethernet, Ethernet, ServeRAID, FC1, FC1 Ethernet
ServeRAID
Ethernet
FC1
FC1
Ethernet, Ethernet, FC1, FC1, FC1
Ethernet
Ethernet
FC1
FC1
FC1
Ethernet, SCSI SE, Gigabit, Gigabit, FC2
Ethernet
SCSI SE
Gigabit
Gigabit
FC2
Ethernet, SCSI SE, Gigabit, PRO/1000,
FC2
Ethernet
SCSI SE
PRO/1000
Gigabit
FC2
Ethernet, SCSI SE, PRO/1000,
PRO/1000, FC2
Ethernet
SCSI SE
PRO/1000
PRO/1000
FC2
Ethernet, SCSI SE, Gigabit, Gigabit, FC1
Ethernet
SCSI SE
Gigabit
Gigabit
FC1
Ethernet, SCSI SE, Gigabit, PRO/1000,
FC1
Ethernet
SCSI SE
Gigabit
PRO/1000
FC1
Ethernet, SCSI SE, PRO/1000,
PRO/1000, FC1
Ethernet
SCSI SE
PRO/1000
PRO/1000
FC1
Ethernet, SCSI SE, Gigabit, ServeRAID,
FC2
Ethernet
ServeRAID
SCSI SE
Gigabit
FC2
Ethernet, SCSI SE, PRO/1000,
ServeRAID, FC2
Ethernet
ServeRAID
SCSI SE
PRO/1000
FC2
Ethernet, SCSI SE, Gigabit, ServeRAID,
FC1
Ethernet
ServeRAID
SCSI SE
Gigabit
FC1
Ethernet, SCSI SE, PRO/1000,
ServeRAID, FC1
Ethernet
ServeRAID
SCSI SE
PRO/1000
FC1
Appendix H. Adapter placement tables
197
Summary of Contents for totalstorage 326
Page 8: ...viii Model 326 User s Reference...
Page 10: ...x Model 326 User s Reference...
Page 20: ...8 Model 326 User s Reference...
Page 64: ...52 Model 326 User s Reference...
Page 88: ...76 Model 326 User s Reference...
Page 134: ...122 Model 326 User s Reference...
Page 144: ...132 Model 326 User s Reference...
Page 146: ...134 Model 326 User s Reference...
Page 166: ...154 Model 326 User s Reference...
Page 182: ...170 Model 326 User s Reference...
Page 192: ...180 Model 326 User s Reference...
Page 214: ...202 Model 326 User s Reference...
Page 232: ...220 Model 326 User s Reference...
Page 238: ...226 Model 326 User s Reference...
Page 239: ......