215-801-000
Optical Drive Test Aborted
Explanation:
Optical Drive Test Aborted. Unable to communicate with driver.
Severity:
Warning
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1.
Make sure that the DSA Diagnostic code is at the latest level.
2.
Run the test again.
3.
Check the drive cabling for loose or broken connections at both ends or damage to the cable. Replace the cable if
damage is present.
4.
Run the test again.
5.
Check system firmware level and upgrade if necessary.The installed firmware level can be found in the DSA
Diagnostic Event Log within the Firmware/VPD section for this component.
6.
Run the test again.
Related Links:
v
v
v
215-802-000
Optical Drive Test Aborted
Explanation:
Optical Drive Test Aborted. A read error was encountered.
Severity:
Warning
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1.
Insert a new CD or DVD into the drive and wait for 15 seconds for the media to be recognized. Rerun the test.
2.
Check the drive cabling for loose or broken connections at both ends or damage to the cable. Replace the cable if
damage is present.
3.
Run the test again.
4.
If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the
next corrective action.
Related Links:
v
v
v
215-801-000 • 215-802-000
728
System x3650 M4 BD Type 5466: Installation and Service Guide
Summary of Contents for System x3650 M4 BD Type 5466
Page 1: ...System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 2: ......
Page 3: ...System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 8: ...vi System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 102: ...86 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 130: ...114 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 178: ...162 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 189: ...v Type 2 SAS Figure 84 Cable routing Chapter 6 Removing and replacing components 173 ...
Page 606: ...590 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 766: ...750 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 775: ...Taiwan Class A compliance statement Notices 759 ...
Page 776: ...760 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 778: ...762 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 784: ...768 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 785: ......
Page 786: ... Part Number 00KC029 Printed in USA 1P P N 00KC029 ...