PCI 2 : PCI 3 :
806f0023-2101ffff
Watchdog Timer expired for [WatchdogElementName]. (IPMI Watchdog)
Explanation:
This message is for the use case when an implementation has detected a Watchdog Timer Expired.
May also be shown as 806f00232101ffff or 0x806f00232101ffff
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0368
SNMP Trap ID:
Automatically notify Support:
No
User response:
No action; information only.
806f0028-2101ffff
Sensor [SensorElementName] is unavailable or degraded on management system
[ComputerSystemElementName]. (TPM Cmd Failures)
Explanation:
This message is for the use case when an implementation has detected a Sensor is Unavailable or
degraded.
May also be shown as 806f00282101ffff or 0x806f00282101ffff
Severity:
Warning
Alert Category:
Warning - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0398
SNMP Trap ID:
60
Automatically notify Support:
No
User response:
1.
Turn off the server and disconnect the power cords. Reconnect the power cords and restart the server.
2.
If the problem remains, (trained technician only) replace the system board.
806f0107-0301ffff
An Over-Temperature Condition has been detected on [ProcessorElementName]. (CPU 1)
Explanation:
This message is for the use case when an implementation has detected an Over-Temperature Condition
Detected for Processor.
May also be shown as 806f01070301ffff or 0x806f01070301ffff
Severity:
Error
Alert Category:
Critical - Temperature
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0036
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
1.
Make sure that the fans are operating. There are no obstructions to the airflow (front and rear of the server), the
air baffles are in place and correctly installed, and the server cover is installed and completely closed.
2.
Make sure that the heat sink for microprocessor n is installed correctly.
3.
(Trained technician only) Replace microprocessor n. (n = microprocessor number)
806f0023-2101ffff • 806f0107-0301ffff
Appendix A. Integrated management module II (IMM2) error messages
373
Summary of Contents for System x3650 M4 BD Type 5466
Page 1: ...System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 2: ......
Page 3: ...System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 8: ...vi System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 102: ...86 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 130: ...114 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 178: ...162 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 189: ...v Type 2 SAS Figure 84 Cable routing Chapter 6 Removing and replacing components 173 ...
Page 606: ...590 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 766: ...750 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 775: ...Taiwan Class A compliance statement Notices 759 ...
Page 776: ...760 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 778: ...762 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 784: ...768 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 785: ......
Page 786: ... Part Number 00KC029 Printed in USA 1P P N 00KC029 ...