Removing and replacing Tier 1 CRUs
Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at
your request, you will be charged for the installation.
The illustrations in this document might differ slightly from your hardware.
Removing a hot-swap hard disk drive
Use this information to remove a hot-swap hard disk drive.
About this task
Attention:
v
To avoid damage to the drive connectors, make sure that the server cover is in
place and fully closed whenever you install or remove a drive.
v
To make sure that there is adequate system cooling, do not operate the server for
more than 2 minutes without either a drive or a filler panel installed in each bay.
To remove a hot-swap hard disk drive, complete the following steps:
Procedure
1.
Read the safety information that begins on page “Safety” on page vii,
“Handling static-sensitive devices” on page 34 and “Installation guidelines” on
page 32.
2.
Press the release latch on the side of the drive front.
3.
Grasp the handle and pull the hot-swap drive assembly out of the drive bay.
4.
If you are instructed to return the hot-swap drive, follow all packaging
instructions, and use any packaging materials for shipping that are supplied to
you.
Figure 77. Hot-swap drive removal
166
System x3650 M4 BD Type 5466: Installation and Service Guide
Summary of Contents for System x3650 M4 BD Type 5466
Page 1: ...System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 2: ......
Page 3: ...System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 8: ...vi System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 102: ...86 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 130: ...114 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 178: ...162 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 189: ...v Type 2 SAS Figure 84 Cable routing Chapter 6 Removing and replacing components 173 ...
Page 606: ...590 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 766: ...750 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 775: ...Taiwan Class A compliance statement Notices 759 ...
Page 776: ...760 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 778: ...762 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 784: ...768 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 785: ......
Page 786: ... Part Number 00KC029 Printed in USA 1P P N 00KC029 ...