800b010a-1e85ffff
Redundancy Lost for [RedundancySetElementName] has asserted. (Cooling Zone 5)
Explanation:
This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b010a1e85ffff or 0x800b010a1e85ffff
Severity:
Error
Alert Category:
Critical - Fan Failure
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0802
SNMP Trap ID:
11
Automatically notify Support:
No
User response:
1.
Make sure that the connectors on fan n are not damaged.
2.
Make sure that the fan n connectors on the system board are not damaged.
3.
Make sure that the fans are correctly installed.
4.
Reseat the fans.
5.
Replace the fans. (n = fan number)
800b010c-2581ffff
Redundancy Lost for [RedundancySetElementName] has asserted. (Backup Memory)
Explanation:
This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b010c2581ffff or 0x800b010c2581ffff
Severity:
Error
Alert Category:
Critical - Memory
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0802
SNMP Trap ID:
41
Automatically notify Support:
No
User response:
1.
Check the system-event log for DIMM failure events (uncorrectable or PFA) and correct the failures.
2.
Re-enable mirroring in the Setup utility.
800b0309-1301ffff
Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for
[RedundancySetElementName] has asserted. (Power Resource)
Explanation:
This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded
or Fully Redundant to Non-redundant:Sufficient.
May also be shown as 800b03091301ffff or 0x800b03091301ffff
Severity:
Warning
Alert Category:
Warning - Redundant Power Supply
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0806
SNMP Trap ID:
10
Automatically notify Support:
No
User response:
1.
Non-redundant sufficient: Power load will be handled by remaining power supply, though the system may
throttle to avoid a power supply over-current condition.
800b010a-1e85ffff • 800b0309-1301ffff
356
System x3650 M4 BD Type 5466: Installation and Service Guide
Summary of Contents for System x3650 M4 BD Type 5466
Page 1: ...System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 2: ......
Page 3: ...System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 8: ...vi System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 102: ...86 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 130: ...114 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 178: ...162 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 189: ...v Type 2 SAS Figure 84 Cable routing Chapter 6 Removing and replacing components 173 ...
Page 606: ...590 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 766: ...750 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 775: ...Taiwan Class A compliance statement Notices 759 ...
Page 776: ...760 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 778: ...762 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 784: ...768 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Page 785: ......
Page 786: ... Part Number 00KC029 Printed in USA 1P P N 00KC029 ...