3-1 (Page 20 of 24). Firmware Error Codes.
Error Code
Description
Action / Possible Failing FRU
40B00000
The operating system surveillance
interval exceeded.
1. Surveillance mode control is from
the Service Processor(SP) Menus.
2. Verify that the Operating System
(OS) Heartbeat Utility is installed
and has been activated.
3. Check for errors or unusual
conditions that might prevent the
OS from reporting Heartbeat
messages; such as system dump,
machine check or checkstop error.
Review the error log.
4. I/O board. (See notes on 3-1.)
5. Service processor.
6. If the problem persists, call the
support center for assistance.
40B00100
Surveillance timeout on CPU 1.
1. Check for errors or unusual
conditions that might prevent the
CPU from reporting Heartbeat
messages; such as system dump,
machine check or checkstop error.
Review the Service Processor error
log.
2. Replace the CPU card.
40B00101
Surveillance timeout on CPU 2.
1. Check for errors or unusual
conditions that might prevent the
CPU from reporting Heartbeat
messages; such as system dump,
machine check or checkstop error.
Review the Service Processor error
log.
2. Replace the CPU card.
40B00102
Surveillance timeout on CPU 3.
1. Check for errors or unusual
conditions that might prevent the
CPU from reporting Heartbeat
messages; such as system dump,
machine check or checkstop error.
Review the Service Processor error
log.
2. Replace the CPU card.
40B00103
Surveillance timeout on CPU 4.
1. Check for errors or unusual
conditions that might prevent the
CPU from reporting Heartbeat
messages; such as system dump,
machine check or checkstop error.
Review the Service Processor error
log.
2. Replace the CPU card.
Chapter 3. Error Code to FRU Index
3-21
Summary of Contents for RS6000 - 7026 - H70
Page 1: ...RS 6000 7025 F50 Series IBM Service Guide SA38 0541 01...
Page 6: ...vi Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 18: ...Rear View 1 2 Service Guide...
Page 23: ...Operator Panel Chapter 1 Reference Information 1 7...
Page 24: ...System Data Flow 1 8 Service Guide...
Page 120: ...AIX and Physical Location Code Reference Table 3 48 Service Guide...
Page 121: ...Chapter 3 Error Code to FRU Index 3 49...
Page 208: ...5 40 Service Guide...
Page 211: ...Covers Removal 1 Open the door Chapter 6 Removal and Replacement Procedures 6 3...
Page 217: ...b Remove the I O planar cover Chapter 6 Removal and Replacement Procedures 6 9...
Page 222: ...5 Close the door 6 14 Service Guide...
Page 231: ...4 Remove the screw holding the adapter Chapter 6 Removal and Replacement Procedures 6 23...
Page 240: ...4 Remove the Processor card s as described in Processor Card on page 6 35 6 32 Service Guide...
Page 247: ...Chapter 6 Removal and Replacement Procedures 6 39...
Page 251: ...Replacement Replace in reverse order Chapter 6 Removal and Replacement Procedures 6 43...
Page 255: ...Chapter 7 Parts Information Chapter 7 Parts Information 7 1...
Page 256: ...7 2 Service Guide...
Page 278: ...A 16 Service Guide...
Page 318: ...C 4 Service Guide...
Page 333: ...expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix D Modem Configurations D 15...
Page 340: ...D 22 Service Guide...
Page 344: ...E 4 Service Guide...
Page 353: ...VPD vital product data 3 93 Index X 9...
Page 354: ...X 10 Service Guide...
Page 356: ...X 12 Service Guide...
Page 357: ......