Table
3-1 (Page 19 of 24). Firmware Error Codes.
Error Code
Description
Action / Possible Failing FRU
401110C2
A low
−
12 voltage reading detected.
1. Power supply.
2. I/O board. (See notes on 3-1.)
40111101
Power good signal low on either
processor card 1 or processor card 2.
(If the system is running, refer to the
AIX error log to find out which
processor card is failing. If the system
is not running, refer to the Service
Processor error log.)
Replace failing processor card
40111102
Wrong processor cards plugged into
the system.
1. Remove cards
2. Verify part numbers
3. Install valid cards
40200001
An unknown cooling problem detected.
Cooling problem; check system fans.
40200021
A CPU temperature warning detected.
Over temperature on CPU card.
40200023
A critical CPU temperature condition
detected.
Critical temperature on CPU card.
40200031
An I/O board temperature warning
detected.
Over temperature on I/O board.
40200033
A critical I/O board temperature
condition detected.
Critical temperature on I/O board.
40200041
A memory temperature warning
detected.
Over temperature on the Memory Card.
40200043
A critical memory temperature condition
detected.
Critical temperature on the Memory
Card.
40210011
A slow fan detected.
Check:
1. Room operating temperature.
2. System fans.
40A00000
System firmware IPL failure.
1. Surveillance mode control is from
the Service Processor (SP) Menus.
2. Verify that the system firmware
supports Service Processor
surveillance.
3. CPU card.
4. I/O board. (See notes on 3-1.)
5. Service processor.
6. If the problem persists, call the
support center for assistance.
3-20
Service Guide
Summary of Contents for RS6000 - 7026 - H70
Page 1: ...RS 6000 7025 F50 Series IBM Service Guide SA38 0541 01...
Page 6: ...vi Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 18: ...Rear View 1 2 Service Guide...
Page 23: ...Operator Panel Chapter 1 Reference Information 1 7...
Page 24: ...System Data Flow 1 8 Service Guide...
Page 120: ...AIX and Physical Location Code Reference Table 3 48 Service Guide...
Page 121: ...Chapter 3 Error Code to FRU Index 3 49...
Page 208: ...5 40 Service Guide...
Page 211: ...Covers Removal 1 Open the door Chapter 6 Removal and Replacement Procedures 6 3...
Page 217: ...b Remove the I O planar cover Chapter 6 Removal and Replacement Procedures 6 9...
Page 222: ...5 Close the door 6 14 Service Guide...
Page 231: ...4 Remove the screw holding the adapter Chapter 6 Removal and Replacement Procedures 6 23...
Page 240: ...4 Remove the Processor card s as described in Processor Card on page 6 35 6 32 Service Guide...
Page 247: ...Chapter 6 Removal and Replacement Procedures 6 39...
Page 251: ...Replacement Replace in reverse order Chapter 6 Removal and Replacement Procedures 6 43...
Page 255: ...Chapter 7 Parts Information Chapter 7 Parts Information 7 1...
Page 256: ...7 2 Service Guide...
Page 278: ...A 16 Service Guide...
Page 318: ...C 4 Service Guide...
Page 333: ...expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix D Modem Configurations D 15...
Page 340: ...D 22 Service Guide...
Page 344: ...E 4 Service Guide...
Page 353: ...VPD vital product data 3 93 Index X 9...
Page 354: ...X 10 Service Guide...
Page 356: ...X 12 Service Guide...
Page 357: ......