Step 1540-11
The last FRU installed or one of its attached devices is probably defective.
1. Make sure the diagnostic CD-ROM is inserted into the CD-ROM drive.
2. Turn the power off and remove the power cable.
3. Starting with the last installed adapter, disconnect one attached device and
cable.
4. Reinstall the power cable.
5. Turn the power on.
6. If the Console Selection screen is displayed, choose the system console.
7. After the keyboard indicator appears, press the F5 key on the directly-attached
keyboard or the number 5 key on an ASCII terminal keyboard.
8. Enter the appropriate password when prompted to do so.
Is the "Please define the System Console" screen displayed?
NO
Repeat this step until the defective device or cable is identified or all the
devices and cables have been disconnected.
If all the devices and cables have been removed, then one of the FRUs
remaining in the system unit is defective.
To test each FRU, exchange the FRUs in the following order:
1. Adapter (last one installed)
2. I/O planar
If the I/O planar or a network adapter is replaced, see notes on page
2-1.
3. Power supply.
If the symptom did not change and all the FRUs have been exchanged,
call your service support person for assistance.
If the symptom has changed check for loose cards, cables, and obvious
problems. If you do not find a problem return to “Step 1540-1” on
page 2-18 in this MAP and follow the instructions for the new symptom.
YES
The last device or cable that you disconnected is defective or if the last
device is the CPU card go to “Step 1540-3” on page 2-20.
Exchange the defective device or cable.
Go to "MAP 410: Repair Checkout" in the
IBM RS/6000 Diagnostic
Information for Multiple Bus Systems.
2-30
Service Guide
Summary of Contents for RS6000 - 7026 - H70
Page 1: ...RS 6000 7025 F50 Series IBM Service Guide SA38 0541 01...
Page 6: ...vi Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 18: ...Rear View 1 2 Service Guide...
Page 23: ...Operator Panel Chapter 1 Reference Information 1 7...
Page 24: ...System Data Flow 1 8 Service Guide...
Page 120: ...AIX and Physical Location Code Reference Table 3 48 Service Guide...
Page 121: ...Chapter 3 Error Code to FRU Index 3 49...
Page 208: ...5 40 Service Guide...
Page 211: ...Covers Removal 1 Open the door Chapter 6 Removal and Replacement Procedures 6 3...
Page 217: ...b Remove the I O planar cover Chapter 6 Removal and Replacement Procedures 6 9...
Page 222: ...5 Close the door 6 14 Service Guide...
Page 231: ...4 Remove the screw holding the adapter Chapter 6 Removal and Replacement Procedures 6 23...
Page 240: ...4 Remove the Processor card s as described in Processor Card on page 6 35 6 32 Service Guide...
Page 247: ...Chapter 6 Removal and Replacement Procedures 6 39...
Page 251: ...Replacement Replace in reverse order Chapter 6 Removal and Replacement Procedures 6 43...
Page 255: ...Chapter 7 Parts Information Chapter 7 Parts Information 7 1...
Page 256: ...7 2 Service Guide...
Page 278: ...A 16 Service Guide...
Page 318: ...C 4 Service Guide...
Page 333: ...expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix D Modem Configurations D 15...
Page 340: ...D 22 Service Guide...
Page 344: ...E 4 Service Guide...
Page 353: ...VPD vital product data 3 93 Index X 9...
Page 354: ...X 10 Service Guide...
Page 356: ...X 12 Service Guide...
Page 357: ......