ServerGuide
problems
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Types
7971
and
7972,”
on
page
59
to
determine
which
components
are
CRUs
and
which
components
are
FRUs.
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
The
ServerGuide
™
Setup
and
Installation
CD
will
not
start.
1.
Make
sure
that
the
CD
or
DVD
drive
is
associated
with
the
blade
server
that
you
are
configuring.
2.
Make
sure
that
the
blade
server
supports
the
ServerGuide
program.
3.
If
the
startup
(boot)
sequence
settings
have
been
changed,
make
sure
that
the
CD
or
DVD
drive
is
first
in
the
startup
sequence.
The
operating-system
installation
program
continuously
loops.
Make
more
space
available
on
the
hard
disk.
The
ServerGuide
program
will
not
start
the
operating-system
CD.
Make
sure
that
the
operating-system
CD
is
supported
by
the
ServerGuide
program.
See
the
ServerGuide
Setup
and
Installation
CD
label
for
a
list
of
supported
operating-system
versions.
The
operating
system
cannot
be
installed;
the
option
is
not
available.
Make
sure
that
the
blade
server
supports
the
operating
system.
If
it
does,
either
no
logical
drive
is
defined
(SAS
RAID
servers),
or
the
ServerGuide
System
Partition
is
not
present.
Run
the
ServerGuide
program
and
make
sure
that
setup
is
complete.
Service
processor
problems
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Types
7971
and
7972,”
on
page
59
to
determine
which
components
are
CRUs
and
which
components
are
FRUs.
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
The
management-module
reports
a
general
monitor
failure.
Disconnect
the
BladeCenter
unit
from
all
electrical
sources,
wait
for
30
seconds,
reconnect
the
BladeCenter
unit
to
the
electrical
sources,
and
restart
the
blade
server.
If
the
problem
remains,
see
“Solving
undetermined
problems”
on
page
56,
and
the
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
or
Problem
Determination
and
Service
Guide
for
your
BladeCenter
unit.
36
BladeCenter
LS21
Type
7971
and
LS41
Type
7972:
Problem
Determination
and
Service
Guide
Summary of Contents for LS21 - BladeCenter - 7971
Page 1: ...BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Page 8: ...vi BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Page 16: ...xiv BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Page 78: ...62 BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Page 116: ...100 BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Page 128: ...112 BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Page 129: ......
Page 130: ...Part Number 24R9695 Printed in USA 1P P N 24R9695...