Each
Ethernet
controller
on
the
system
board
is
routed
to
a
different
I/O-module
in
I/O-module
bay
1
or
bay
2.
The
routing
from
an
Ethernet
controller
to
I/O-module
bay
will
vary
based
on
blade
server
type
and
the
operating
system
that
is
installed.
See
“Blade
server
Ethernet
controller
enumeration”
for
information
about
how
to
determine
the
routing
from
an
Ethernet
controller
to
an
I/O-module
bay
for
the
blade
server.
Note:
Other
types
of
blade
servers,
such
as
the
BladeCenter
HS20
Type
8678
blade
server,
that
are
installed
in
the
same
BladeCenter
unit
as
the
BladeCenter
LS21
Type
7971
or
LS41
Type
7972
blade
server
might
have
different
Ethernet
controller
routing.
See
the
documentation
that
comes
with
the
other
blade
servers
for
information.
You
do
not
have
to
set
any
jumpers
or
configure
the
controllers
for
the
blade
server
operating
system.
However,
you
must
install
a
device
driver
to
enable
the
blade
server
operating
system
to
address
the
Ethernet
controllers.
For
device
drivers
and
information
about
configuring
the
Ethernet
controllers,
see
the
Broadcom
NetXtreme
Gigabit
Ethernet
Software
CD
that
comes
with
the
blade
server.
For
updated
information
about
configuring
the
controllers,
see
http://www.ibm.com/bladecenter/.
The
Ethernet
controllers
in
your
blade
server
support
failover,
which
provides
automatic
redundancy
for
the
Ethernet
controllers.
Without
failover,
you
can
have
only
one
Ethernet
controller
from
each
server
attached
to
each
virtual
LAN
or
subnet.
With
failover,
you
can
configure
more
than
one
Ethernet
controller
from
each
server
to
attach
to
the
same
virtual
LAN
or
subnet.
Either
one
of
the
integrated
Ethernet
controllers
can
be
configured
as
the
primary
Ethernet
controller.
If
you
have
configured
the
controllers
for
failover
and
the
primary
link
fails,
the
secondary
controller
takes
over.
When
the
primary
link
is
restored,
the
Ethernet
traffic
switches
back
to
the
primary
Ethernet
controller.
(See
the
operating-system
device-driver
documentation
for
information
about
configuring
for
failover.)
Important:
To
support
failover
on
the
blade
server
Ethernet
controllers,
the
Ethernet
switch
modules
in
the
BladeCenter
unit
must
have
identical
configurations.
Blade
server
Ethernet
controller
enumeration
The
enumeration
of
the
Ethernet
controllers
in
a
blade
server
is
operating-system
dependent.
You
can
verify
the
Ethernet
controller
designations
that
a
blade
server
uses
through
the
operating-system
settings.
The
routing
of
an
Ethernet
controller
to
a
particular
I/O-module
bay
depends
on
the
type
of
blade
server.
You
can
verify
which
Ethernet
controller
is
routed
to
which
I/O-module
bay
by
using
the
following
test:
1.
Install
only
one
Ethernet
switch
module
or
pass-thru
module
in
I/O-module
bay
1.
2.
Make
sure
that
the
ports
on
the
switch
module
or
pass-thru
module
are
enabled
(click
I/O-module
Tasks
→
Management
→
Advanced
Management
in
the
management
module
Web-based
user
interface).
3.
Enable
only
one
of
the
Ethernet
controllers
on
the
blade
server.
Note
the
designation
that
the
blade
server
operating
system
has
for
the
controller.
98
BladeCenter
LS21
Type
7971
and
LS41
Type
7972:
Problem
Determination
and
Service
Guide
Summary of Contents for LS21 - BladeCenter - 7971
Page 1: ...BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Page 8: ...vi BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Page 16: ...xiv BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Page 78: ...62 BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Page 116: ...100 BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Page 128: ...112 BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Page 129: ......
Page 130: ...Part Number 24R9695 Printed in USA 1P P N 24R9695...