Removing
and
replacing
FRUs
FRUs
must
be
installed
only
by
trained
service
technicians.
The
illustrations
in
this
document
might
differ
slightly
from
your
hardware.
Removing
a
microprocessor
and
heat
sink
Read
the
following
important
guidelines
before
removing
a
microprocessor
that
is
not
faulty
(for
example,
when
you
are
replacing
the
system
board
assembly).
Attention:
Do
not
use
an
alcohol
wipe
with
the
microprocessor.
If
you
are
not
replacing
a
defective
heat
sink
or
microprocessor,
the
thermal
material
on
the
heat
sink
and
microprocessor
will
remain
effective
if
you
complete
the
following
steps:
1.
Carefully
handle
the
heat
sink
and
microprocessor
when
removing
or
installing
these
components.
Do
not
touch
the
thermal
material
or
otherwise
allow
it
to
become
contaminated.
2.
In
a
dual-microprocessor
blade
server
or
MPE
unit,
the
microprocessor
and
the
heat
sink
are
a
matched
set.
First
transfer
the
heat
sink
and
microprocessor
from
one
socket
to
the
new
system
board;
then,
transfer
the
other
heat
sink
and
microprocessor.
(This
will
make
sure
that
the
thermal
material
remains
evenly
distributed
between
each
heat
sink
and
microprocessor.)
Notes:
v
The
heat-sink
FRU
is
packaged
with
the
thermal
material
applied
to
the
underside.
This
thermal
material
is
not
available
as
a
separate
FRU.
The
heat
sink
must
be
replaced
when
new
thermal
material
is
required,
such
as
when
a
defective
microprocessor
is
replaced
or
if
the
thermal
material
is
contaminated
or
has
come
in
contact
with
another
object
other
than
its
paired
microprocessor.
v
The
microprocessor
FRU
for
this
blade
server
and
MPE
unit
includes
a
heat
sink.
v
A
heat-sink
FRU
can
be
ordered
separately
if
the
thermal
material
becomes
contaminated.
90
BladeCenter
LS21
Type
7971
and
LS41
Type
7972:
Problem
Determination
and
Service
Guide
Summary of Contents for LS21 - BladeCenter - 7971
Page 1: ...BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Page 8: ...vi BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Page 16: ...xiv BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Page 78: ...62 BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Page 116: ...100 BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Page 128: ...112 BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Page 129: ......
Page 130: ...Part Number 24R9695 Printed in USA 1P P N 24R9695...