Table
5-1 (Page 7 of 9). Service Request Numbers
SRN
FRU List
%
Problem
60000
SSA adapter card (See the
installation and service guide
for the using system.)
100
Description: The SSA adapter is missing
from the expected configuration.
Action: Verify that the SSA adapter card
is installed in the expected slot of the
using-system.
If it is in the expected slot, exchange
the FRU for a new FRU.
If it is not in the expected slot, enter
the diag -a command, and answer the
questions that are displayed.
7xxxx
Disk drive module (See
“Hot-Swappable Disk Drives”
on page 7-13.)
Backplane assembly (See
“SCSI or SSA Backplane” on
page 7-66.)
80
20
Description: An SP module is missing
from the expected configuration of the
SSA loop.
Action: Replace the FRUs one at a time.
Go to MAP 410: Repair Checkout in
Diagnostic Information for Multiple Bus
Systems to verify each repair.
D0000
Disk drive module (See
“Hot-Swappable Disk Drives”
on page 7-13.)
100
Description: The using system cannot
configure the disk drive module. This is
probably a software problem.
Action:
1. Try again to configure the disk drive
module.
2. If the problem remains, go to “Soft-
ware and Microcode Errors” on
page 5-2 before exchanging the FRU.
D0100
Disk drive module (See
“Hot-Swappable Disk Drives”
on page 7-13.)
100
Description: Unable to clear a disk drive
module reservation.
Action: Exchange the FRU for a new
FRU.
D0101
Disk drive module (See
“Hot-Swappable Disk Drives”
on page 7-13.)
100
Description: The disk drive module has
been reserved since the diagnostics
started. The disk drive module is in use.
Action: Release the disk drive module,
and run the diagnostics again.
D0200
Disk drive module (See
“Hot-Swappable Disk Drives”
on page 7-13.)
100
Description: The disk drive module timed
out while the diagnostics were running.
Action: Rerun the diagnostics. If the
problem remains, exchange the FRU for a
new FRU.
D0300
Disk drive module (See
“Hot-Swappable Disk Drives”
on page 7-13.)
100
Description: The disk drive module failed
the diagnostic test.
Action: Exchange the FRU for a new
FRU.
Chapter 5. SSA Software and Microcode Errors
5-9
Summary of Contents for H Series
Page 1: ...RS 6000 Enterprise Server Model H Series IBM Installation and Service Guide SA38 0547 01...
Page 14: ...xiv RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 34: ...1 18 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 108: ...2 74 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 182: ...3 74 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 254: ...6 40 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 285: ...Chapter 7 Removal and Replacement Procedures 7 31...
Page 322: ...7 68 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 323: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Page 336: ...8 14 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 348: ...A 12 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 422: ...E 28 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 426: ...F 4 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 433: ...Index X 7...
Page 434: ...X 8 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 437: ......