Table
3-1 (Page 25 of 40). Firmware Error Codes.
Error Code
Description
Action / Possible Failing FRU
40110003
Voltage is present, but not detected
on one processor card. (If the
system is running, refer to the AIX
error log to find out which processor
card is failing. If the system is not
running, refer to the service
processor error log.)
For Model H50:
1. Check cable between CPU card and
PDB for proper seating.
2. Replace CPU card.
3. Replace cable between CPU card and
PDB.
4. Replace PDB.
For Model H70: Replace power supply.
40110004
For Model H50: Loss of redundant
power supply. (If the system is
running, refer to the AIX error log to
find out which processor card is
failing. If the system is not running,
refer to the service processor error
log.) For Model H70: Low voltage
detected in power supply main
enclosure.
For Model H50:
1. Power supply.
2. PDB.
3. I/O board. (See notes on 3-1.)
For Model H70:
D
1. Check fan monitor cable to connector
D
on I/O Board.
D
2. Power supply.
40110005
For Model H50: Loss of redundant
power supply and a DASD fan.
(Refer to the service processor error
log to determine which fan and
power supply is failing.) For Model
H70: Fan warning detected in power
supply main enclosure.
For Model H50:
1. Power supply.
2. DASD fan.
For Model H70:
D
1. Check fan monitor cable to connector
D
on I/O Board.
D
2. Power supply.
40110006
Fan failure detected in power supply
main enclosure
D
1. Check fan monitor cable to connector
D
on I/O Board.
D
2. Power supply.
40110007
Thermal warning detected in power
supply main enclosure
D
1. Check fan monitor cable to connector
D
on I/O Board.
D
2. Power supply.
40110008
Thermal failure detected in power
supply main enclosure
D
1. Check fan monitor cable to connector
D
on I/O Board.
D
2. Power supply.
40110009
High 5.0 volt detected in power
supply main enclosure
D
1. Check fan monitor cable to connector
D
on I/O Board.
D
2. Power supply.
D
40110015
D
Service processor detects less than
D
200V minimum required to run the
D
system.
D
1. Check power coming into the system
D
to ensure it is 200-240V.
D
2. Power supply.
4011000A
High 5.0 RA volt detected in power
supply main enclosure
D
1. Check fan monitor cable to connector
D
on I/O Board.
D
2. Power supply.
3-26
RS/6000 Enterprise Server Model H Series Installation and Service Guide
Summary of Contents for H Series
Page 1: ...RS 6000 Enterprise Server Model H Series IBM Installation and Service Guide SA38 0547 01...
Page 14: ...xiv RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 34: ...1 18 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 108: ...2 74 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 182: ...3 74 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 254: ...6 40 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 285: ...Chapter 7 Removal and Replacement Procedures 7 31...
Page 322: ...7 68 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 323: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Page 336: ...8 14 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 348: ...A 12 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 422: ...E 28 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 426: ...F 4 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 433: ...Index X 7...
Page 434: ...X 8 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 437: ......