Table
5-1 (Page 1 of 9). Service Request Numbers
SRN
FRU List
%
Problem
10101
Disk drive module (See
“Hot-Swappable Disk Drives”
on page 7-13.)
100
Description: Disk drive motor stopped.
The disk drive module is bad.
Action: If this SRN was received by one
disk drive module only, then exchange
that disk drive module.
10112
None
–
Description: Format degraded. A format
operation has been ended before it has
completed.
Action: Use the Format service aid to
format the disk drive module.
1xxxx
Disk drive module (See
“Hot-Swappable Disk Drives”
on page 7-13.)
100
Description: Disk drive module error.
Action: Exchange the FRU for a new
FRU.
Note: In this SRN, an x represents a
digit from 0 to F.
20PAA
Disk drive module (See
“Hot-Swappable Disk Drives”
on page 7-13.)
SSA adapter card (See the
installation and service guide
for the using system.)
External SSA Cables
Backplane assembly (See
“SCSI or SSA Backplane” on
page 7-66.)
Internal SSA Cable
45
45
6
2
2
Description: An open SSA link has been
detected.
Action: Run the Link Verification Service
Aid to isolate the failure. If the SSA
service aids are not available:
When the failing device is an SSA
Hot-Swap Disk Drive, go to “SSA
Maintenance Analysis Procedures
(MAPs)” on page 2-65.
When the failing device is not an SSA
Hot-Swap Disk Drive, go to the
service information for that device.
21PAA
to
29PAA
Disk drive module (See
“Hot-Swappable Disk Drives”
on page 7-13.)
SSA adapter card (See the
installation and service guide
for the using system.)
External SSA Cables Back-
plane assembly (See “SCSI
or SSA Backplane” on
page 7-66.)
Internal SSA Cable
45
45
6
2
2
Description: An SSA threshold-exceeded-
link error has been detected.
Action: Run the Link Verification Service
Aid to isolate the failure. If the SSA
service aids are not available:
When the failing device is an SSA
Hot-Swap Disk Drive, go to “SSA
Maintenance Analysis Procedures
(MAPs)” on page 2-65.
When the failing device is not an SSA
Hot-Swap Disk Drive, go to the
service information for that device.
2A002
Disk drive module (See
“Hot-Swappable Disk Drives”
on page 7-13.)
SSA adapter card (See the
installation and service guide
for the using system.)
50
50
Description: Async code 02 has been
received. A software error has probably
occurred.
Action: Go to “Software and Microcode
Errors” on page 5-2 before exchanging
any FRUs.
Chapter 5. SSA Software and Microcode Errors
5-3
Summary of Contents for H Series
Page 1: ...RS 6000 Enterprise Server Model H Series IBM Installation and Service Guide SA38 0547 01...
Page 14: ...xiv RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 34: ...1 18 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 108: ...2 74 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 182: ...3 74 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 254: ...6 40 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 285: ...Chapter 7 Removal and Replacement Procedures 7 31...
Page 322: ...7 68 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 323: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Page 336: ...8 14 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 348: ...A 12 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 422: ...E 28 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 426: ...F 4 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 433: ...Index X 7...
Page 434: ...X 8 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 437: ......