Table
1.
Abbreviated
list
of
firmware
error
codes
(continued)
Error
code
Failing
device
or
problem
found
Suggested
action
25C10003
One
component
in
a
DIMM
pair
is
either
unsupported
or
defective,
or
a
DIMM
pair
contains
unmatched
components.
Note:
For
additional
information
about
DIMMs,
see
“Installing
memory
modules”
on
page
24.
1.
Make
sure
that
all
the
DIMMs
in
the
blade
server
are
supported.
Replace
all
the
unsupported
DIMMs.
2.
Make
sure
that
the
DIMMs
are
installed
in
matched
pairs.
If
the
DIMMs
are
not
installed
in
matched
pairs,
reinstall
them
in
matched
pairs.
3.
Make
sure
that
the
DIMMs
are
correctly
seated.
If
necessary,
reseat
the
DIMMs.
4.
Restart
the
blade
server.
5.
Remove
and
reinstall
the
DIMMs
one
at
a
time
until
the
failing
DIMM
is
isolated.
Replace
the
defective
DIMM.
26020008
PCI
device
firmware
code
evaluation
error.
If
the
location
code
identifies
a
slot:
1.
Reseat
the
adapter
and
restart
the
blade
server.
2.
Replace
the
adapter.
3.
Check
the
http://www.ibm.com/support
Web
site
for
system
firmware
updates.
Apply
the
latest
update,
if
one
is
available.
4.
If
an
update
is
not
available,
contact
a
system
administrator
for
assistance.
If
the
location
code
identifies
the
system
board,
replace
the
system-board
assembly.
Contact
a
service
support
representative
for
assistance.
2803000A
The
Hypervisor
function
to
get
or
set
the
time-of-day
(TOD)
reported
an
error.
Errors
that
are
reported
against
the
real-time
clock
can
be
caused
by
low
battery
voltage
and
(more
rarely)
by
power
outages
that
occur
during
normal
system
usage.
These
errors
are
warnings
that
the
real-time
clock
data
content
must
be
re-established,
and
do
not
require
any
component
or
FRU
replacement
unless
the
problem
remains.
When
one
of
these
errors
occurs,
the
time
and
date
information
has
been
lost.
Reset
the
system
date
and
time
through
the
operating
system
that
you
installed.
If
the
problem
remains,
perform
the
following
steps:
1.
Check
for
system
or
service
processor
firmware
updates.
Apply
the
latest
updates,
if
they
are
available.
2.
Replace
the
battery
in
the
blade
server.
For
additional
information,
see
the
Hardware
Maintenance
and
Troubleshooting
Guide.
Note:
After
you
replace
the
battery,
the
blade
server
is
automatically
reconfigured;
however,
you
must
reset
the
system
date
and
time
through
the
operating
system
that
you
installed.
3.
If
the
problem
remains,
replace
the
blade
server.
Contact
a
service
support
representative
for
assistance.
2B208888
Operating-system
termination
request
has
been
received.
This
is
an
informational
message.
No
action
is
required.
76
BladeCenter
JS20
Type
8842:
Installation
and
User’s
Guide
Summary of Contents for BladeCenter JS20
Page 3: ...BladeCenter JS20 Type 8842 Installation and User s Guide ...
Page 46: ...34 BladeCenter JS20 Type 8842 Installation and User s Guide ...
Page 120: ...108 BladeCenter JS20 Type 8842 Installation and User s Guide ...
Page 131: ......
Page 132: ... Part Number 31R1749 Printed in USA 1P P N 31R1749 ...