Table
1.
Abbreviated
list
of
firmware
error
codes
(continued)
Error
code
Failing
device
or
problem
found
Suggested
action
20D008
xx
Failure
to
access
VPD
data.
Where
xx
is:
xx
Description
0E,
0F
Machine
type
or
model
10,
11
System
serial
number
16,
17
Universal
unique
identifier
(UUID)
1E
Startup
(boot)
mode
Perform
the
system
checkout
procedure.
See
“System
checkout”
on
page
48.
20D00900
The
blade
server
failed
to
generate
a
UUID
value.
1.
Replace
the
memory
in
the
blade
server.
2.
Replace
the
system-board
assembly.
Contact
a
service
support
representative
for
assistance.
20D00901
The
blade
server
failed
to
communicate
with
the
service
processor.
Have
the
blade
server
serviced.
Contact
a
service
support
representative
for
assistance.
20D00902
The
blade
server
is
starting
from
the
permanent
firmware
code
page
(PERM
image).
If
the
blade
server
was
set
to
start
from
the
permanent
firmware
code
page
(PERM
image),
this
is
an
informational
message.
If
it
was
not,
this
indicates
that
the
blade
server
was
unable
to
start
from
the
temporary
firmware
code
page
(TEMP
image).
Go
to
“Recovering
the
system
firmware
code”
on
page
84.
Have
the
blade
server
serviced.
20D00903
The
blade
server
failed
to
find
the
/openprom
package.
This
is
most
likely
a
software
error.
Have
the
blade
server
serviced.
Contact
a
service
support
representative
for
assistance.
20D1000A
The
blade
server
failed
to
send
the
startup-failure
message
to
the
service
processor.
Perform
the
system
checkout
procedure.
See
“System
checkout”
on
page
48.
20D10004
The
blade
server
failed
to
locate
service
processor
device-tree
node.
Perform
the
system
checkout
procedure.
See
“System
checkout”
on
page
48.
20D10005
The
blade
server
failed
to
restart.
Perform
the
system
checkout
procedure.
See
“System
checkout”
on
page
48.
20D10006
The
blade
server
failed
to
restart
a
partition.
Perform
the
system
checkout
procedure.
See
“System
checkout”
on
page
48.
20D10007
Partition
firmware
error
before
stdout
ready.
Perform
the
system
checkout
procedure.
See
“System
checkout”
on
page
48.
20D10010
Stack
underflow
from
the
Fibre
Channel
adapter.
1.
Check
the
http://www.ibm.com/support
Web
site
for
microcode
updates
for
the
Fibre
Channel
adapter.
Apply
the
latest
update,
if
one
is
available.
2.
If
an
update
is
not
available,
contact
a
system
administrator
for
assistance.
3.
Perform
the
system
checkout
procedure.
See
“System
checkout”
on
page
48.
Chapter
7.
Solving
problems
67
Summary of Contents for BladeCenter JS20
Page 3: ...BladeCenter JS20 Type 8842 Installation and User s Guide ...
Page 46: ...34 BladeCenter JS20 Type 8842 Installation and User s Guide ...
Page 120: ...108 BladeCenter JS20 Type 8842 Installation and User s Guide ...
Page 131: ......
Page 132: ... Part Number 31R1749 Printed in USA 1P P N 31R1749 ...