20A80005
The
trivial
file
transfer
protocol
(TFTP)
failed.
1.
Make
sure
that
the
BOOTP
server
is
correctly
configured
for
this
client.
2.
Check
the
network
connection.
If
the
network
connection
is
good,
retry
the
operation.
If
there
is
no
network
connection,
contact
your
network
administrator.
3.
If
there
are
no
problems
with
the
BOOTP
server
or
the
network
connection,
replace
the
system-board
assembly.
Contact
a
service
support
representative
for
more
information.
20A80006
The
startup
image
is
too
large.
1.
Make
sure
that
the
BOOTP
server
is
correctly
configured
for
this
client.
2.
Check
the
network
connection.
If
the
network
connection
is
good,
retry
the
operation.
If
there
is
no
network
connection,
contact
your
network
administrator.
3.
If
there
are
no
problems
with
the
BOOTP
server
or
the
network
connection,
replace
the
system-board
assembly.
Contact
a
service
support
representative
for
more
information.
20A80100
A
SAN
device
was
found
in
the
boot
list;
however,
the
ibm,fw-fcpdisk
alias
name
has
not
been
defined
in
the
/alias
node.
Type
the
setup-fc-disk
command
at
the
open
firmware
prompt
and
press
Enter;
then,
restart
the
blade
server.
20A80102
The
ibm,fw-fcpdisk
alias
is
not
a
SAN
device.
Run
the
setup-fc-disk
utility.
20A80104
The
disk2
alias
was
found
and
copied
to
the
ibm,fw-fcpdisk
alias.
This
is
an
informational
message.
No
action
is
required.
20A80110
The
ibm,fw-fcpdisk
alias
was
modified.
This
is
an
informational
message.
No
action
is
required.
20D0000F
The
device
failed
the
self-test;
error
or
location
code
information
might
not
be
available.
v
If
a
location
code
is
specified,
replace
the
device
at
that
location.
v
Perform
the
system
checkout
procedure.
See
“System
checkout”
on
page
48.
20D00010
The
device
failed
the
self-test;
cannot
locate
package.
1.
If
a
location
code
is
reported
with
the
error,
replace
the
device
at
that
location
code.
2.
Replace
the
system-board
assembly.
Contact
a
service
support
representative
for
more
information.
20D00011
The
run-time
extraction
services
(RTAS)
program
attempt
to
allocate
memory
failed.
Perform
the
system
checkout
procedure.
See
“System
checkout”
on
page
48.
66
BladeCenter
JS20
Type
8842:
Installation
and
User’s
Guide
Summary of Contents for BladeCenter JS20
Page 3: ...BladeCenter JS20 Type 8842 Installation and User s Guide ...
Page 46: ...34 BladeCenter JS20 Type 8842 Installation and User s Guide ...
Page 120: ...108 BladeCenter JS20 Type 8842 Installation and User s Guide ...
Page 131: ......
Page 132: ... Part Number 31R1749 Printed in USA 1P P N 31R1749 ...