Error
code
Failing
device
or
problem
found
Suggested
action
25A80210
Setenv/$Setenv
parameter
error;
name
contains
a
null
character.
If
the
problem
remains,
replace
the
battery
in
the
blade
server.
For
additional
information,
see
the
Hardware
Maintenance
and
Troubleshooting
Guide.
Note:
After
you
replace
the
battery,
you
must
reset
the
system
date
and
time
through
the
operating
system
that
you
installed.
If
the
problem
still
remains,
replace
the
system-board
assembly.
Contact
a
service
support
representative
for
assistance.
25A80211
Setenv/$Setenv
parameter
error;
value
contains
a
null
character.
If
the
problem
remains,
replace
the
battery
in
the
blade
server.
For
additional
information,
see
the
Hardware
Maintenance
and
Troubleshooting
Guide.
Note:
After
you
replace
the
battery,
you
must
reset
the
system
date
and
time
through
the
operating
system
that
you
installed.
If
the
problem
still
remains,
replace
the
system-board
assembly.
Contact
a
service
support
representative
for
assistance.
25A80998
NVRAMRC
script
evaluation
error.
Perform
the
following
steps
to
remove
the
NVRAMRC
script:
1.
Boot
to
the
open
firmware
prompt.
2.
Enter
the
following
command:
0
0
"
nvramrc"
$setenv
If
the
problem
remains,
contact
your
system
administrator
for
assistance.
25A80999
NVRAMRC
script
evaluation
error;
stack
unbalanced
on
completion.
This
is
a
firmware
debug
environment
error.
No
action
is
required.
No
component
replacement
is
required.
If
the
problem
remains,
have
the
blade
server
serviced.
25000000
The
blade
server
failed
to
set
the
Write
Delay
(WRDLY)
bit
in
the
memory
controller
register.
1.
Start
from
the
PERM
flash
image
to
reflash
the
TEMP
image
for
recovery.
See
“Recovering
the
system
firmware
code”
on
page
84.
2.
If
the
problem
remains,
replace
the
blade
server.
Contact
a
service
support
representative
for
assistance.
25C00000
No
DIMMs
were
detected.
Note:
For
additional
information
about
DIMMs,
see
“Installing
memory
modules”
on
page
24.
1.
Make
sure
that
the
DIMMs
are
correctly
seated.
If
necessary,
reseat
the
DIMMs.
2.
Restart
the
blade
server.
3.
Perform
the
system
checkout
procedure.
See
“System
checkout”
on
page
48.
If
the
problem
remains,
replace
the
system-board
assembly.
Contact
a
service
support
representative
for
assistance.
Chapter
7.
Solving
problems
73
Summary of Contents for BladeCenter JS20
Page 3: ...BladeCenter JS20 Type 8842 Installation and User s Guide ...
Page 46: ...34 BladeCenter JS20 Type 8842 Installation and User s Guide ...
Page 120: ...108 BladeCenter JS20 Type 8842 Installation and User s Guide ...
Page 131: ......
Page 132: ... Part Number 31R1749 Printed in USA 1P P N 31R1749 ...