Pre-installation Guidelines
Before installing the cable management tray in a rack, determine which cable management tray rack
mount position is best for you by examining the following:
Location in the rack where the switch will be installed (refer to “Pre-installation Guidelines” on
page 13).
Depth of the rack in to which the switch will be installed.
Space required for ventilation. A minimum of 15 cm (6 in.) is required between the rear of the 8265
and the nearest wall or vertical surface.
Room required for module cables to bend.
Proximity of other devices in the rack and their installation or environmental requirements.
Figure 2 shows cable management tray rack mount positions.
Flush Mount
5/8" (1.6 cm) Recess
2 1/8" (5.4 cm) Recess
2 3/4" (7.0 cm) Recess
Figure 2. Cable Management Tray Rack Mount Positions
Table 2 provides cable management tray rack settings.
Table 2. Rack Mount Settings for Cable Management Tray
Setting
Description
Flush mount
Mounts the tray flush with the front of the rack.
5/8-inch (1.6 cm) recess
Recesses the tray 5/8-inch (1.6 cm) from the front of the rack.
2 1/8-inch (5.4 cm) recess
Recesses the tray 2 1/8-inch (5.4 cm) from the front of the rack.
2 3/4-inch (7.0 cm) recess
Recesses the tray 2 3/4-inch (7.0 cm) from the front of the rack.
Select any rack position that is at least 28 inches (approximately 71 cm) from the top of the rack or the
next higher unit in the rack.
Be sure to select a rack position that leaves you enough room to install the cable management tray below
the installed switch.
Chapter 3. Installing the Chassis
9
Summary of Contents for 8265 Nways ATM Switch
Page 1: ...8265 Nways ATM Switch IBM Installation Guide SA33 0441 02...
Page 2: ......
Page 3: ...8265 Nways ATM Switch IBM Installation Guide SA33 0441 02...
Page 8: ...vi IBM 8265 Installation Guide...
Page 10: ...viii IBM 8265 Installation Guide...
Page 12: ...x IBM 8265 Installation Guide...
Page 14: ...xii IBM 8265 Installation Guide...
Page 32: ...18 IBM 8265 Installation Guide...
Page 52: ...38 IBM 8265 Installation Guide...
Page 68: ...54 IBM 8265 Installation Guide...
Page 88: ...Models 17S Serial Number Located on the 8265 chassis label 74 IBM 8265 Installation Guide...
Page 98: ......
Page 101: ......
Page 102: ...IBM SA33 441 2...