b. Remove the CPSW2 that has the incorrect jumper setting
c. Set the jumper to the correct position
d. Re-install the CPSW2 module
e. Power on the 8265.
Problems When Hot-Plugging:
When installing CPSW2 modules into an already powered-on
8265, the following problems will occur if the power control jumper is in the incorrect position:
1. If the jumper is set to the ON (up) position, and you do not have a Controller module installed:
The LEDs on the CPSW2 module will not illuminate, even when the TEST LED button is pressed.
Media modules cannot be connected to the network or enabled.
To resolve this problem you must:
a. Power off the 8265.
b. Either:
Install a Controller module should you not wish to use the integrated power control of the
CPSW2 module, or
Remove the CPSW2 module and move the jumper to the OFF (down) position. Then re-install
the module
c. Power on the 8265.
2. If the jumper is set to the OFF position, but a Controller module is already installed:
a. Power off the 8265.
b. Either:
Install a Controller module should you not wish to use the integrated power control of the
CPSW2 module, or
Remove the CPSW2 module and move the jumper to the OFF (down) position. Then re-install
the module
c. Power on the 8265.
The CPSW2 module cannot take over power control from the Controller module.
Media modules cannot be connected to the network or enabled.
To resolve this problem you must:
a. Power off the 8265.
b. Either:
Remove the Controller module, should you wish to use the integrated power control functions
of the CPSW2 module, or
Remove the CPSW2 module and move the jumper to the ON (up) position. Then re-install the
module
c. Power on the 8265.
58
IBM 8265: Installation Guide
Summary of Contents for 8265 Nways ATM Switch
Page 1: ...8265 Nways ATM Switch IBM Installation Guide SA33 0441 02...
Page 2: ......
Page 3: ...8265 Nways ATM Switch IBM Installation Guide SA33 0441 02...
Page 8: ...vi IBM 8265 Installation Guide...
Page 10: ...viii IBM 8265 Installation Guide...
Page 12: ...x IBM 8265 Installation Guide...
Page 14: ...xii IBM 8265 Installation Guide...
Page 32: ...18 IBM 8265 Installation Guide...
Page 52: ...38 IBM 8265 Installation Guide...
Page 68: ...54 IBM 8265 Installation Guide...
Page 88: ...Models 17S Serial Number Located on the 8265 chassis label 74 IBM 8265 Installation Guide...
Page 98: ......
Page 101: ......
Page 102: ...IBM SA33 441 2...