v
Power/reset control (power-on, hard and soft shutdown, hard and soft reset,
schedule power control).
v
Query power-supply input power.
v
ROM-based IMM firmware flash updates.
v
Serial redirect.
v
Serial over LAN (SOL).
v
System-event log.
v
When one of the two microprocessors reports an internal error, the server
disables the defective microprocessor and restarts with the one good
microprocessor.
The IMM also provides the following remote server management capabilities
through the OSA SMBridge management utility program:
v
Command-line interface (IPMI Shell)
The command-line interface provides direct access to server management
functions through the IPMI 2.0 protocol. Use the command-line interface to issue
commands to control the server power, view system information, and identify the
server. You can also save one or more commands as a text file and run the file
as a script.
v
Serial over LAN
Establish a Serial over LAN (SOL) connection to manage servers from a remote
location. You can remotely view and change the UEFI settings, restart the server,
identify the server, and perform other management functions. Any standard Telnet
client application can access the SOL connection.
Using the embedded hypervisor
The VMware ESXi embedded hypervisor is available on server models that come
with an installed USB embedded hypervisor flash device. The USB flash device
comes installed in the USB connector on the system board. Hypervisor is
virtualization software that enables multiple operating systems to run on a host
system at the same time. The USB flash device is required to activate the
hypervisor functions.
To start using the embedded hypervisor functions, you must add the USB flash
device to the boot order in the Setup utility.
To add the USB flash device to the boot order, complete the following steps:
1. Turn on the server.
Note:
Approximately 20 seconds after the server is connected to AC power, the
power-control button becomes active.
2. When the prompt
<F1> Setup
is displayed, press F1.
3. From the Setup utility main menu, select
Boot Manager
.
4. Select
Add Boot Option
; then, select
Embedded Hypervisor
. Press Enter, and
then select Esc.
5. Select
Change Boot Order
and then select
Commit Changes
; then, press
Enter.
6. Select
Save Settings
and then select
Exit Setup
.
312
IBM System x3400 M3 Types 7378 and 7379: Problem Determination and Service Guide
Summary of Contents for 7378
Page 1: ...IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Page 40: ...22 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Page 158: ...140 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Page 166: ...148 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Page 187: ...Chapter 5 Removing and replacing server components 169...
Page 192: ...174 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Page 194: ...176 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Page 196: ...178 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Page 318: ...300 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Page 352: ...334 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Page 360: ...342 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Page 361: ......
Page 362: ...Part Number 00KC028 Printed in USA 1P P N 00KC028...