Off Line Diagnostic Error Codes
D-11
Error
Number
Description
Failure
Percent
(%)
Failing
Function
Codes
Source
401-841
K
LSA
C59
C90
C61
C63
40
20
20
10
10
Description: Channel reset and POS.
POS4 register error.
Action: Use MAP 0210.
401-842
K
LSA
C59
C90
C61
C63
40
20
20
10
10
Description: Channel reset and POS.
POS2 register error.
Action: Use MAP 0210.
401-843
K
LSA
C59
C90
C61
C63
40
20
20
10
10
Description: Channel reset and POS.
NCR SCRATCH A register error.
Action: Use MAP 0210.
401-844
K
LSA
C59
C90
C61
C63
40
20
20
10
10
Description: Channel reset and POS.
SCSI Bus control lines error.
Action: Use MAP 0210.
401-845
K
LSA
C59
C90
C61
C63
40
20
20
10
10
Description: Channel reset and POS.
Missing ACK signal error.
Action: Use MAP 0210.
401-846
K
LSA
C59
C90
C61
C63
40
20
20
10
10
Description: Channel reset and POS.
Pending ACK signal error.
Action: Use MAP 0210.
401-847
K
LSA
C59
C90
C61
C63
40
20
20
10
10
Description: Channel reset and POS.
Missing DMA interrupt error during transfer.
Action: Use MAP 0210.
401-848
K
LSA
C59
C90
C61
C63
40
20
20
10
10
Description: Channel reset and POS.
DMA status error.
Action: Use MAP 0210.
401-849
K
LSA
C59
C90
C61
C63
40
20
20
10
10
Description: Channel reset and POS.
Missing DMA interrupt after transfer.
Action: Use MAP 0210.
401-850
K
LSA
C59
C90
C61
C63
40
20
20
10
10
Description: Channel reset and POS.
DFE or SSI signal not asserted.
Action: Use MAP 0210.
Summary of Contents for 7015-R50
Page 1: ...7015 Models R30 R40 and R50 CPU Enclosure Installation and Service Guide...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 34: ...1 20 Service Guide...
Page 214: ...6 10 Service Guide Detail 5 CPU Module 2 of 3 26 27 29 30 31 32 33 34 28 35...
Page 216: ...6 12 Service Guide Detail 6 CPU Module 3 of 3 36 37...
Page 252: ...B 8 Installation and Service Guide...
Page 288: ...Service Guide D 30...
Page 299: ......