4-52
Service Guide
System Planar
Note: Refer to “Handling Static-Sensitive Devices” on page 4-14 before removing or
installing memory cards.
Removal
1. Do the “interlock Cable Connector” removal procedure on page 4-43.
2. Do the “Memory Card, CPU Card, and I/O Card” removal procedure on page 4-45 to
remove all of the memory cards, CPU cards, and I/O card.
3. R50 CPU Enclosures: Remove the seven screws holding the front guide bracket, and
then lift the bracket out of the CPU Module.