Service Guide
D-20
Error
Number
Description
Failure
Percent
(%)
Failing
Function
Codes
Source
403-527
K
C59
C61
C63
50
25
25
Description: CPU to BUMP interrupt.
XIRR4 register error.
Action: Use MAP 0210.
403-528
K
C59
C61
C63
50
25
25
Description: CPU to BUMP interrupt.
IOD-HW-STS register error.
Action: Use MAP 0210.
403-529
K
C59
C61
C63
50
25
25
Description: CPU to BUMP interrupt.
XIRR0 register error.
Action: Use MAP 0210.
403-530
K
C59
C61
C63
50
25
25
Description: CPU to BUMP interrupt.
XIRR4 register error.
Action: Use MAP 0210.
403-531
K
C59
C61
C63
50
25
25
Description: CPU to BUMP interrupt.
IRR register error.
Action: Use MAP 0210.
403-540
K
C59
C61
C63
50
25
25
Description: UART to CPU interrupt.
IRR register error, bit i#1.
Action: Use MAP 0210.
403-541
K
C59
C61
C63
50
25
25
Description: UART to CPU interrupt.
IRR register error, bit i#0.
Action: Use MAP 0210.
403-542
K
C59
C61
C63
50
25
25
Description: UART to CPU interrupt.
No External interrupt.
Action: Use MAP 0210.
403-543
K
C59
C61
C63
50
25
25
Description: UART to CPU interrupt.
External interrupt return error.
Action: Use MAP 0210.
403-544
K
not
available
resource
Description: UART to CPU interrupt. Target processor error.
Action: Use MAP 0210.
403-545
K
C59
C61
C63
50
25
25
Description: UART to CPU interrupt.
XIRR4 register error.
Action: Use MAP 0210.
403-546
K
C59
C61
C63
50
25
25
Description: UART to CPU interrupt.
IRR register error.
Action: Use MAP 0210.
403-550
K
C59
C61
C63
50
25
25
Description: CPU to CPU interrupt.
MFRR register error.
Action: Use MAP 0210.
403-551
K
C59
C61
C63
50
25
25
Description: CPU to CPU interrupt.
External interrupt return error.
Action: Use MAP 0210.
403-552
K
C59
C61
C63
50
25
25
Description: CPU to CPU interrupt.
No external interrupt.
Action: Use MAP 0210.
403-553
K
C59
C61
C63
50
25
25
Description: CPU to CPU interrupt.
Target processor error.
Action: Use MAP 0210.
Summary of Contents for 7015-R50
Page 1: ...7015 Models R30 R40 and R50 CPU Enclosure Installation and Service Guide...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 34: ...1 20 Service Guide...
Page 214: ...6 10 Service Guide Detail 5 CPU Module 2 of 3 26 27 29 30 31 32 33 34 28 35...
Page 216: ...6 12 Service Guide Detail 6 CPU Module 3 of 3 36 37...
Page 252: ...B 8 Installation and Service Guide...
Page 288: ...Service Guide D 30...
Page 299: ......