Using SystemGuard
2-41
Setting Fast IPL through the Maintenance Menu
1. Enter the MAINTENANCE MENU.
2. Enter
8
to select the
SET PARAMETERS
menu.
3. Enter
4
from the SET PARAMETERS menu to select the
MISCELLANEOUS
PARAMETERS
Menu.
4. Option
3
in this menu should show the current status of the Fast IPL flag. If it is disabled,
simply enter
3
, and the flag changes to enabled.
Fast IPL is now enabled and lasts one reboot.
Setting Fast IPL through AIX
1. Log into AIX as user
root.
2. Type in the following command to find the
index of the Fast IPL flag and also the current
flag value:
mpcfg –df
Following is the output of the command:
Index Name Value
1 Remote Authorization 0
2 Autoservice IPL 0
3 BUMP Console 1
4 Dial–Out Authorization 0
5 Set Mode to Normal When Booting 0
6 Electronic Mode Switch from Service Line 0
7 Boot Multi–User AIX in Service 0
8 Extended Tests 1
9 Power On Tests in Trace Mode 0
10 Power On Tests in Loop Mode 0
11 Fast IPL 0
3. The index is number
11
, and, generally, the current value is zero (
0
), which means
disabled.
4. Type the following command to change the status of the Fast IPL flag to enabled:
mpcfg –cf 11 1
Where
11
is the index and
1
the value itself;
c
is for change and
f
for diagnostics flags.
5. Type the following command just to verify the flag is changed:
mpcfg –df
Summary of Contents for 7015-R50
Page 1: ...7015 Models R30 R40 and R50 CPU Enclosure Installation and Service Guide...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 34: ...1 20 Service Guide...
Page 214: ...6 10 Service Guide Detail 5 CPU Module 2 of 3 26 27 29 30 31 32 33 34 28 35...
Page 216: ...6 12 Service Guide Detail 6 CPU Module 3 of 3 36 37...
Page 252: ...B 8 Installation and Service Guide...
Page 288: ...Service Guide D 30...
Page 299: ......