3-1540-20
Service Guide
Step 20
(from Step 1)
A message should be displayed with the flashing 269. Find the message in the table and do the listed
action.
Message Displayed
Perform the Listed Action(s)
269 - NO BOOTABLE
Go to Step 21.
269 - NO DEVICE
Go to Step 13.
269 - NO DEV TYPE
Go to Step 22.
Step 21
(from Step 20)
In the following order, exchange the FRUs that have not been exchanged.
1. SCSI adapter
2. I/O Planar
3. I/O Card
4. Flex Cable
After each exchange try loading diagnostics from the CD–ROM to determine if the FRU
fixed the problem.
Were you able to identify the failing FRU?
NO
Go to Step 13.
YES
Replace the failing FRU. Go to “Map 0410: Repair Checkout” in the
Diagnostic Information For Micro Channel Bus Systems..
Step 22
(from Step 20)
In the following order, exchange the FRUs that have not been exchanged.
1. CD–ROM drive
After each exchange try loading diagnostics from the CD–ROM to determine if the FRU
fixed the problem.
Were you able to identify the failing FRU?
NO
Go to Step 13.
YES
Replace the failing FRU. Go to “Map 0410: Repair Checkout” in the
Diagnostic Information For Micro Channel Bus Systems..
Summary of Contents for 7015-R50
Page 1: ...7015 Models R30 R40 and R50 CPU Enclosure Installation and Service Guide...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 34: ...1 20 Service Guide...
Page 214: ...6 10 Service Guide Detail 5 CPU Module 2 of 3 26 27 29 30 31 32 33 34 28 35...
Page 216: ...6 12 Service Guide Detail 6 CPU Module 3 of 3 36 37...
Page 252: ...B 8 Installation and Service Guide...
Page 288: ...Service Guide D 30...
Page 299: ......