Manual
ibaPQU-S
62
Issue 1.3
“Analog” tab
Figure 34: EN50160 submodule: Mains signalling voltage
– “Analog” tab
The EN50160 submodule: Mains signalling voltage calculates the harmonics 1-50 and
the interharmonics 1-50 for each input channel plus the fundamental frequency and the
DC component, in 3 second measurement intervals. In the signal display, the signals are
grouped by input. Click the <+> sign before the group name to show the signals of a
group.
Name
The names are assigned by default. To allow an unambiguous identification, they
contain the input channel, the function and the measurement interval. You can addi-
tionally assign two comments by clicking the
icon in the signal name field.
Function, order, unit
Displays the corresponding property
Active
Here you can enable or disable the signal.